Loading...
Hollows-LR 990402 REPORT OF FIELD COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX; 972/406-8023 TESTED FOR N L W DEVELOPMENT GROUP DATE 4/2/99 DALLAS, TEXAS PROJECT HOLLOWS (~ NORTHLAKE WOODLAND OUR REPORT NO. 99128-31 COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPT~,~ NUMBER MOISTURE DRY DI~NSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 472 4/2/99 FG-9.0 1 26.8 92 27.2 90 97 1-A 473 4/2/99 FG-8.0 I 26.8 92 28.4 88 96 1-A 474 4/2/99 FG-7.0 I 26.8 92 29.9 88 96 1-A 475 4/2/99 FG~.0 1 26.8 92 27.3 90 98 - 1-AD 476 4/2/99 FG-5.0 ' I 26.8 92 30.4 88 96 1-A 477 4/2/99 FG-4.0 1 26.8 92 27.1 89 97 1-A 478 4~2/99 FG-3.0 1 26.8 92 30.0 88 96 1-A TEST LOCATION: 472 SANITARY SEWER LINE E AT STATION #1+00 473 SANITARY SEWER LINE E AT STATION #1+00 474 SANITARY SEWER LINE E AT ~TATION #1+00 475 RETEST OF TEST #492 DATED 3/29/99 476 SANITARY SEWER LINE E AT STATION #1+00 477 SANITARY SEWER LINE E AT STATION #1+00 478 TEST PIT BACKFILL AT SANITARY SEWER LINE E AT STATION #1+00 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS ~ ~-- 2 NATURAL SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WlTH SPECIFICATIONS ~espectfully Subm' 3 LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY VVITH SPECIF~CAT!ONS 4 CEMENT TREATED D RETEST Geotechnical Engineering · Construction Materiats Testing · Environmental Engineering · Consulting