Loading...
Hollows-LR 990402 (2) REPORT OF FIELD COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 [Metro) FAX: 972/406-8023 TESTED FOR N L W DEVELOPMENT GROUP DATE 4/2/99 DALLAS, TEXAS PROJECT HOLLOWS (~ NORTHLAKE WOODLAND OUR REPORT NO. 99128-31A COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPT~ NUMBER MOISTURE DRY DENSrrY MOISTURE DRY DENSI'I~ COMPACTION COMMENT* % PCF % PCF 479 4/2/99 FG-2.0 1 26.1 92 27.6 90 97 1 -A 480 4/2/99 FG-1.0 1 26.1 92 29.0 89 97 1-A 481 4~2/99 FG 1 26.1 92 28.1 90 97 1-A 482 4/2/99 FG I 26.1 92 29.2 88 96. 1 -A 483 4/2/99 FG-8.0 I 26.1 92 27.7 90 98 1-A 484 4/2/99 FG-7.0 1 26.1 92 29.8 88 96 1-A 485 4~2/99 FG-6.0 1 26.1 92 28.5 90 98 1-A TEST LOCATION: 479 SANITARY SEWER LINE E AT STATION #1+00 480 SANITARY SEWER LINE E AT STATION #1+00 481 SANITARY SEWER LINE E AT STATION #1+00 482 SANITARY SEWER LINE E AT STATION #1+00 483 TEST PIT BACKFILL AT SANITARY SEWER LINE E AT STATION #1+00 484 TEST PIT BACKFILL AT SANITARY SEWER LINE E AT STATION #1+00 485 TEST PIT BACKFILL AT SANITARY SEWER LINE E AT STATION #1+00 I FILL * A. IN PLACE PERCENT MOISTU,E AND PE,CENTCOMPACTION COMPLY~ITH SPECIFICATIONS ~ ..~ ~.~..~ 2 NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY VVITH SPECIFICATIONS ~pec[~ul~y S 3 LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPEClF)CATIONS 4 CEMENT TREATED O RETEST ~ ALPHATFS.lqNG J4~1~ Geotechnical Engineering · C~tion Materials Testing · Environmental Engineering · Consulting