Gunner Sub-LR 980910 (3) 9200 King Arthur Drive
Dallas, Texas 75247-3610
Phone 214/631-4372 Fax 214/631-4380
CONCRETE COMPRESSION TEST REPORT
Report No.: 55 JobNo.: 1598-0018
Proje~. St. Matin Apartments
Location: Meter Vaults (4) 50' $ BeEline Rd and 100' W
of E Entrance
Contractor.
Reported To: EPI - Mark Morris
Date Cast:
Spedfica'don:
Quantity Represented:
Sampled By.
By Order Of:.
08/19/98
4000 psi (~ 28 days
7/7/7 cu. yds.
W. Kirby/J.T. Bond
(6 x 12 Inch) Nominal Cylinder Size: Area-28.27 SQ. IN.
Field Number. SM081901
Test Date: 08/26/98
Maximum Load, LBS: 103840
Age When Tested, Days: 7
Compressive Strength, PSI: 3670
Average Strength, PSI: 3600
Type Break: Conical (U.N.O.)
Remarks:
SM081902
08/26/98
99400
7
3520
SM081903
09/16/98
28
Laboratory Number.
SM081904
09/16/98
28
7506
Method of Curing: Field
Temperature: Ambient
Time of Sample: 2:30
Source of Concrete:
Fine Aggregate:
Coarse Aggregate:
Water.
Cement:
Fly Ash:
Admixture(s):
2
103 °F
AMi(PM)
Lattimom
Days, Laboratory From
Mix 92 °F
08/21 Transported By: S. Spinks
Air Content 4.0 % Slump
Pick-Up Charge: Yes X
Mix Code: 42 Ticket No.:
Unit Weight
Yield
4.75 Inches
No
7056984
PCF
CF/CY
Distribution:
City of Coppell - Garreth Campbell
EPI - Don Matlock (FAX)
MFC Construction - Dick Dennie
AECC, Inc. - Mark Gottschalt
Signed (~ q/10/~l! (~
Page .
1 of 1
Test Methods: ASTId C 31, C 39, C 143, C 173, C 192, o~ C 1064