Loading...
Gunner Sub-LR 980910 (3) 9200 King Arthur Drive Dallas, Texas 75247-3610 Phone 214/631-4372 Fax 214/631-4380 CONCRETE COMPRESSION TEST REPORT Report No.: 55 JobNo.: 1598-0018 Proje~. St. Matin Apartments Location: Meter Vaults (4) 50' $ BeEline Rd and 100' W of E Entrance Contractor. Reported To: EPI - Mark Morris Date Cast: Spedfica'don: Quantity Represented: Sampled By. By Order Of:. 08/19/98 4000 psi (~ 28 days 7/7/7 cu. yds. W. Kirby/J.T. Bond (6 x 12 Inch) Nominal Cylinder Size: Area-28.27 SQ. IN. Field Number. SM081901 Test Date: 08/26/98 Maximum Load, LBS: 103840 Age When Tested, Days: 7 Compressive Strength, PSI: 3670 Average Strength, PSI: 3600 Type Break: Conical (U.N.O.) Remarks: SM081902 08/26/98 99400 7 3520 SM081903 09/16/98 28 Laboratory Number. SM081904 09/16/98 28 7506 Method of Curing: Field Temperature: Ambient Time of Sample: 2:30 Source of Concrete: Fine Aggregate: Coarse Aggregate: Water. Cement: Fly Ash: Admixture(s): 2 103 °F AMi(PM) Lattimom Days, Laboratory From Mix 92 °F 08/21 Transported By: S. Spinks Air Content 4.0 % Slump Pick-Up Charge: Yes X Mix Code: 42 Ticket No.: Unit Weight Yield 4.75 Inches No 7056984 PCF CF/CY Distribution: City of Coppell - Garreth Campbell EPI - Don Matlock (FAX) MFC Construction - Dick Dennie AECC, Inc. - Mark Gottschalt Signed (~ q/10/~l! (~ Page . 1 of 1 Test Methods: ASTId C 31, C 39, C 143, C 173, C 192, o~ C 1064