Loading...
Hollows-LR 990316 REPORT OF FIELD ALPHA TESTING, INC. COMPACTION TESTS 2209 Wisconsin St., Suite 100 Dollas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR N L W DEVELOPMENT GROUP DATE 3/16/99 DALLAS, TEXAS PROJECT HOLLOWS ~:~ NORTHLAKE WOODLAND OUR REPORT NO. 99128-21 COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID O~TIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY D~NSII'~ COMPACTION COMMENT* % PCF % PCF 312 3/16/99 SG+2.5 2 24.3 95.2 25.0 95 100 1-A 313 3/16/99 SG+3.0 3 23.2 98.2 24.5 97 99 1-A 314 3/16/99 FG 2 24.3 95.2 26.1 90 95 1-A 315 3/16/99 SG+1.5 2 24.3 95.2 24.4 93 97 1-A 316 3/16/99 FG 2 24.3 95.2 24.3 95 100 1-A 317 3/16~99 SG+2.5 2 24.3 95.2 24.8 93 98 1-A 318 3/16/99 SG+3.0 2 24.3 95.2 25.1 92 97 1-A TEST LOCATION: 312 ALLEY 5 AT STATION #7+00 313 ALLEY 5 AT STATION #7+00 314 ALLEY 5 AT STATION #7+00 315 ALLEY 5 AT STATION ~4+00 316 ALLEY 5 AT STATION #4+00 317 ALLEY 5 AT STATION #10+00 318 ALLEY 5 AT STATION #10+00 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURALSUBGRADE B PERCENT COMPACT~ON DOES NOT COMPLY WlTH SPECIFiCATIONS ~RespectfullySubmitted 3 LIME STABILIZED C. PERCENT IN Pt. ACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS f' ..~- 4 CEMENT TREATED D RETEST ~ ALPH~TESTIN~. Geatechnical Engineering · Cons#uc#on Materiats Testing · Environmental Engineering · Consulting