Loading...
Hollows-LR 990316 (2) REPORT OF FIELD ALPHA TESTING, INC. COMPACTION TESTS 2209 Wisconsin St., Suite 100 Dallas, Texas 7~5229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR N L W DEVELOPMENT GROUP DATE 3/16/99 DALLAS, TEXAS PROJECT HOLLOWS ~ NORTHLAKE WOODLAND OUR REPORT NO. 99128-21A COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 319 3/16/99 FG 2 24.3 95.2 25.3 92 97 1-A 320 3/16/99 SG+1.5 3 23.2 98.2 23.9 96 98 1-A 321 3/16/99 SG+2.0 3 23.2 98.2 23.3 98 100 1-A 322 3/16/99 SG+2.5 3 23.2 98.2 23.4 97 98 1-A 323 3/16/99 SG+3.0 2 24.3 95.2 26.2 92 97 1-A 324 3/16/99 FG 2 24.3 95.2 24.9 95 99 1-A 325 3/16/99 FG 2 24.3 95.2 24.8 95 100 1 -A TEST LOCATION: 319 ALLEY 5 AT STATION #10+00 320 ALLEY 5 AT STATION #12+00 321 ALLEY 5 AT STATION #12+00 322 ALLEY 5 AT STATION #12+00 323 ALLEY 5 AT STATION #12+00 324 ALLEY 5 AT STATION #12+00 325 BLOCKA, PAD 8 FILL * A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLYWITH SPECIFICATIONS NATURAL SUBGRAOE B PERCENT COMPACTION DOES NOT COMPLY VVITH SPECIFICATIONS Re~ully Sub CEMENT TREATEDLIME STABILIZED CD RETEsTPERCENT IN PLACE MOISTURE DOES NOT COMPLY WiTH SPECIFICATIONS Geotechnical Engineering · Construcfi(~ Materials Testing · Environmental Engineering · Consulting