Loading...
Gunner Sub-LR 980828 (2)Engineering Co. 9200 King Arthur Drive Dallas, Texas 75247-3610 Phone 214/631-4372 Fax 214/631-4380 CONCRETE COMPRESSION TEST REPORT Report No.: 38 Job No.: Project: St. Matin Apartments Location: Utility Vault - 60' W of East Entrance Architect/Engineer: Contractor: Reported To: EPI - Mark Morris Date: (6 x 12 Inch) Nominal Cylinder Size: Area-28.27 SQ. IN. 1598-0018 08/13/98 Date Cast: Specification: Quantity Represented: Sampled By: By Order Of:. Order Number: 08/06/98 3600 psi (~ 28 days 9/9/9 cu. yds. S. Spinks Laboratory Number. 7327 Field Number: SM080613 Maximum Load, LBS: 107190 Age When Tested, Days: 7 Compressive Strength, PSh 3790 Average Strength, PSI: 3780 SM080614 SM080615 SM080616 106690 7 28 28 3770 Type Break: Conical (U.N.O.) Remarks: Compressive strength complies with specifications. Method of Curing: Field I Days, Laboratory From 08/07 Transported By: S. Spinks Temperature: Ambient 82 °F Mix 90 °F Time of Sample: 7:30 (AM)/PM Source of Concrete: Lattimore Fine Aggregate: Coarse Aggregate: Water: Cement: Fly Ash: Admixture(s): Air Content 4.5 % Slump Pick-Up Charge: Yes X Mix Code: 42 Ticket No.: Unit Weight Yield Distribution: City of Coppell - Ga~e[h Campbell 3.5 Inches No 7056136 PCF CF/CY EPI - Don Matlock (FAX) MFC Construction - Dick Dennie AECC, Inc. - Mark Gottschalt Site Concrete Signed ~/?-?/~JJJ Page Test Meth.ods: ASTM C 31, C 39. C 143, C 173, C 192, or C 1064 4 of..., 4