Loading...
Hollows-LR 990313 (2) REPORT OF FIELD ALPHA TESTING, INC. COMPACTION TESTS 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR N L W DEVELOPMENT GROUP DATE 3/13/99 DALLAS, TEXAS PROJECT HOLLOWS ~ NORTHLAKE WOODLAND OUR REPORT NO. 99128-i8A COPPELL, TEXAS TEST DATA: TEST SOIL ID OPT~UM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE NUMBER .MOISTURE ORY DEN~rI~ MOIGTURE DRY DENsn~ CO~PACT~N COMMENT* % PCF % PCF 233 3/13/99 SG+1.0 3 23.2 98.2 24.4 96 98 1-A 234 3/13/99 FG 3 23.2 98.2 25.9 93 95 1-A 235 3113/99 SG+2.0 3 23.2 98.2 24.3 94 95 1-A 238 3/13/99 SG+2.5 3 23.2 98.2 25.2 95 96 1-A 237 ,, 3/13/99 FG 3 , 23.2 98.2 25.1 98 99 1-A 238 3/13/99 SG+1.5 3 23.2 98.2 23.3 97 99 1-A 239 3/13/99 FG 3 23.2 98.2 24.7 95 96 1-A TEST LOCATION: 233 ALLEY 1 AT STATION #3+50 234 ALLEY 1 AT STATION #3+50 235 ALLEY 1 AT STATION #18+00 236 ALLEY 1 AT STATION #18+00 237 ALLEY 1 AT STATION #18+00 238 ALLEY 5 AT STATION #4+00 239 ALLEY 5 AT STATION #4+00 1. FILL e A. IN PLAC~ PERCENT MOIS"rMRE ANO PERCENT COMPACTIO~ COMPLY wm-I SPECIFICATIONS ..... 2 NATURAL SUBGRAOE S.PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~fl~/Sublllitt~d ./ 3 LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS /. 4 CEMENT TREATED D. RETEST ........ ALPHA~_~/~~. TESTIN .' - Geotechnical Engineering · Construc#on Materials T~ · Environmental Engineering · Consuth'ng