Hollows-LR 990313 (2) REPORT OF FIELD
ALPHA TESTING, INC. COMPACTION TESTS
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR N L W DEVELOPMENT GROUP DATE 3/13/99
DALLAS, TEXAS
PROJECT HOLLOWS ~ NORTHLAKE WOODLAND OUR REPORT NO. 99128-i8A
COPPELL, TEXAS
TEST DATA:
TEST SOIL ID OPT~UM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATE NUMBER .MOISTURE ORY DEN~rI~ MOIGTURE DRY DENsn~ CO~PACT~N COMMENT*
% PCF % PCF
233 3/13/99 SG+1.0 3 23.2 98.2 24.4 96 98 1-A
234 3/13/99 FG 3 23.2 98.2 25.9 93 95 1-A
235 3113/99 SG+2.0 3 23.2 98.2 24.3 94 95 1-A
238 3/13/99 SG+2.5 3 23.2 98.2 25.2 95 96 1-A
237 ,, 3/13/99 FG 3 , 23.2 98.2 25.1 98 99 1-A
238 3/13/99 SG+1.5 3 23.2 98.2 23.3 97 99 1-A
239 3/13/99 FG 3 23.2 98.2 24.7 95 96 1-A
TEST LOCATION:
233 ALLEY 1 AT STATION #3+50
234 ALLEY 1 AT STATION #3+50
235 ALLEY 1 AT STATION #18+00
236 ALLEY 1 AT STATION #18+00
237 ALLEY 1 AT STATION #18+00
238 ALLEY 5 AT STATION #4+00
239 ALLEY 5 AT STATION #4+00
1. FILL e A. IN PLAC~ PERCENT MOIS"rMRE ANO PERCENT COMPACTIO~ COMPLY wm-I SPECIFICATIONS .....
2 NATURAL SUBGRAOE S.PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~fl~/Sublllitt~d
./
3 LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS /.
4 CEMENT TREATED D. RETEST ........ ALPHA~_~/~~. TESTIN .' -
Geotechnical Engineering · Construc#on Materials T~ · Environmental Engineering · Consuth'ng