CONCRETE INSPECTION AND COMPRESSION TEST REPORT
DISTRIBUTION:
CLIENT: North American Communities Archon Group - Angie Rawe
PROJECT: Karrington Apartments North American Communities - Kurt Heinbecker
REPORT DATE: 6."23-00 C.D. Construction - Garreth Campbell
TMI REPORT #: DC00-040-038 CiD' of Coppell - Greg Jones
SPECIFICATIONS PROJECT DATA
Strength (psi): 3000 Placement Date: 5.'23.'00
Slump (in.): N.'A Sampled By: Contractor
Air Content (%.1: N. A Weather: N A
Concrete Temp (~F): N.A Supplier:Mix: N'A
FIELD DATA: SET #1
Ticket a: N 'A Time Batched: N.'A Time Sampled: N 'A
Slump (in.): N. A Air Content (%): N:A Unit Weight (pcl3: N."A
Conc. Temp. I.°F): N.A Ambient Temp. (:F): N:'A Yardage !c.y.l: N.A
Placement Location: Inlets
Sample Location: Inlets
Remarks: Contractor made
CONCRETE COMPRESSION TEST RESULTS
CYLINDERS MOI_DED AND CURED PER ASTM C3 I. TESTED PER ASTM C39. CAPPED PER .\STM (."! 23 !
Set ~ Age Max Load Strength
? Cylinder v.. Test Date Area (sq.in) - Notes
1 (.Days) (lbs) (psi)
05230 l 5.."30/00 7 ......... ('.x h,:der Damaged
052302 6/20/00 28 129820 28.27 4590
052303 6,"20.."00 28 133880 28.27 4740
KAR
052304 Discard
(1) NORMAL CYLINDER SIZE 6" X 12". AREA 28 27 sq. m., UNLESS NOTED ABOVE.
(2) UNBONDED CAI' SYSTEM t. SED UNI_.ESS O-I-HERWISE NO'I'ED ABOVE.
(3 ~ FIELD TESTS A RE PER AP!'LICABI.E ASTM STANDARDS: C138. (": 43. C 172. C231