Loading...
Gunner P2-LR000602 "-' TERRA-MAR, INC. ~-' GEOTECHNICAL ENVIRONMENTAL AND MATERIALS ENGINEERS DALIMS FORT WORTH HOUSTON LONGVIEW AUSTIN 11050,4bles Lane, Dallas'. Texas 75229 Phone:972-488-8800 Fax:972-488-8080 CONCRETE INSPECTION AND COMPRESSION TEST REPORT DISTRIBUTION: CLIENT: North American Communities Archon Group - Angle Rawie PROJECT: Karrington Apartments North American Communities - Kurt Heinbecker REPORT DATE: 6/2/00 C.D. Construction - Garrcth Campbell T:VH REPORT #: DC00-040-017 City, of Coppell - Greg Jones SPECIFICATIONS PROJECT DATA Strength (psi): 3000 Placement Date: 5/2/00 Slump (in.): 5 max Sampled By: S. Adli Air Content (%): ~ - 6 Weather: Clear Concrete Temp (°F): 95 max Supplier/Mix: LMC FIELD DATA: SET # 1 Ticket #: 7086419 Time Batched: 2:26 PM Time Sampled: 3:15 P_'vl Slump (in.): I Air Content (%): 4 Unit Weight (pcf): N/A Conc. Temp. I:'F): 85 Ambient Temp. (°F): 80 Yardage {c.y.): 9:9?09 Placement Location: 2 manholes on line "C" Sample Location: Remarks: CONCRETE COMPRESSION TEST RESULTS CYLINDERS MOLDED .AND CURED PER ASTM C3I. TESTED PER AS'm C3~, CAPPED PER ASTM C617 Set # Age Max Load Area Stren~h Notes 1 Cylinder # Test Date (Days) (lbs) (sq.in) (psi) 050201 5/9/00 7 143140 28.27 5060 050202 §/30/00 28 154130 28.37 5430 050203 §/30/00 28 157710 28.37 5560 KAR 050204 Discard (1) NORMAL CYI_INDER SIZE 6" X 12", AREA 28.2? sq. in., UNLESS NOTED ABOVE. (2) UNBONDED ('AP SYSTEM USED, TYPE A(CONE) FRACTURE UNLESS OTHERWISE NOTED: B [CONE-SPLI'I-~: C~(_'ONE-SHEARI; D (SHEAR): E (COLUMNAR) (3) FIELD IESTS ARE PER APPLICABLE ASTM S'rANDARDS: C138, C143, C172. C231 Additional Distribution: Don Matlock - Fax: 972-906-0608 la . Dry Page 1 of 1 Project.Manager Note: This report is for the exclusive use of the client addressed. This report may not be reproduced except in its entirety, without the written consent of TMI. Results apply only to' above tests.