Gunner P2-LR000526 (3) TERRA-MAR, INC.
GEOTECHNICAL ENVIRONMENTAL .aND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON LONGVIEW .4USTIN
11050 Ables Lane. Dallas. Texas 75229 Phone:972-488-8800
SOIL MOISTURE -DENSITY TEST REPORT
IN-PLACE TESTS BY NUCLEAR METHODS (ASTM D-2922)
CLIENT: North American Communities DISTRIBUTION:
PROJECT: Karrington Apartments Archon Group - Angle Rawie
TMI REPORT #: DC00-040-023 N. American Communities - Kurt Heinbecker
REPORT DATE: 5~26~00 C.D. Construction - Doyle Dameron
PAGE I OF 2 City o£Coppell - Garreth Campbell
Cib' of Coppell - Greg Jones
Don Matlock - Fax: 972-906-0608
SPECIFICATIONS TEST DATA
Percent Compaction: 95 Date Tested: 5." 15/00
,Moisture Content {%): Opt. -2 to '4 Technician: J. Moreland
MATERIAL REFERENCE CURVE DATA
CURVE TEST O.M.C. M.D.D.
NO. METHOD MATERIAL DESCRIPTION (%) (PCF)
6782 ASTM-D6L)8 Dark Brown & Olive Brown Clay w: Limestone Fragments 27.1 91.1
6689 ASTM-D698 Dark Brown & Tan Clay w/Limestone Fragments 21.7 98.4
6653 ASTM-DagS Olive Clay 19.9 101.1
3 .~S'rM-D60S Olive & Broxvn Sandy Clay 17.3 107.6
IN-PLACE TEST RESULTS
DENSITY ,,*,ND MOISTURE TESTS ARE PER ASTM D2922. D3017. RESPECTIVELY
TEST ELEVATION REF. % WET DRY %
NO. OR LIFT LOCATION CURVE MOIST. DENSITY DENSITY DENSITY
1R F6-3 Re-test #17 on 5-9-00 6782 29.1 118.5 91.8 101
2R F6-2 Re-test #18 on 5-9-00 6689 25.4 123.8 98.7 100
3 F6 8" sewer ~ station 11+47 center line 6782 29.2 117.7 91.1 100
4 F6-1 8" water line ~ station 3+50 center line 6782 28.5 116.5 90.7 100
5 F6 8" water line @ station 3+49 center line 3 20.9 124.0 102.6 95
6 F6-1 8" water line ~ station 7+00 center line 3 20.8 128.7 106.5 99
7 F6 8" water line ~ station 6+99 center line 6782 28.8 117.2 91.0 100
8 F6-1 8" water line ~ station 9+25 center line 6689 22.9 115.6 94.1 96
9 F6 Apt. bldg # 18 of SW comer 10' N. & 20' W. 6689 20.8 118.4 98.0 100
10 F6 Apt. bldg #18 of SW comer 10' N. & 45' W. 6689 24.5 118.4 95.1 97
GAUGE SN. 3141 DENSITY STD. COUNT: 3829 MOIS/L'RE STD. C(_)tJN'F: 434
"R" AFTER TEST NUMBER INDICATES RETEST. GAUGE MANUF:\CTI:'RI_:R:
* INDICATES FAILURE TO COMPLY WITH PROJECT SPE('IFICATIONS GAUGE MODEL NO.:
REMARKS:
Project .Manager/i 7~
Note: This report is for the exclusive use of the Client addressed. This report may not be reproduced except in its
entirety, without the written consent of TMI. Results apply only to above tests.