ST0004-LR010807 ~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax.'(g72) 488~8080 _--- ~ - Concrete Compression Test Report Client: The City of Coppell Report Distribution: (1) The City of Coppell Project: Freeport Parkway Pavement (1) Quantam Contracting Repair TMI Report No.: DC01-066-027 Report Date: 08/07/2001 Specifications Test Data Strength 4000 psi @ 28 Days Placement Date 07/24/2001 Slump 5 in max Sampled By Mohammed A. Kashem Air Content 3 % min 8 % max Weather Clear Concrete Temperature n/a Supplier/Mix Hanson/9638 Ambient Temperature n/a Air Content Method ASTM C-231-B Ticket Number: 907380 Time Batched: 11:45 am Time Sampled: 1:00 pm Slump: 3.5 in Air Content: 5.0 % Unit Weight: n/a Concrete Temperature: 96° F Ambient Temperature: 90° F Yardage (c.y.): 10 of 120 Placement Location: Paving at Freeport Parkway Sample Location: Paving at Freeport Parkway at North bound lane, Station 1+55 Cylinder Age. Max Load Area Strength Fracture Set # # Test Date (days) (lbs. force) (sq.in.) (psi} Type 1 07240101 07/31/2001 7 109740 28.18 ~ unbonded cap I 07240102 07/31/2001 7 115450 28.18 ~ unbonded cap 1 07240103 08/07/2001 14 127340 28.27 unbonded cap 1 07240104 08/07/2001 14 127020 28.27 unbonded cap 1 07240105 08/21/2001 28 1 07240106 08/21/2001 28 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. TERRA-MAR, INC. . The results presented in this repo~ )ecific items tested. This report was produced for the exclusive use of the client. Any reproduction of this repod, or any part therein, the express written consent of TMI. Page t of l