Loading...
Hunterwood-CS 840813GINN, INC. CONSULTING ENGINEERS TO: FRON: DATE: SUBJECT: Hr. Hark S~eeney Coppell, Texas OINlq, ~NC., City Engineer August 13, 1984 Coppell Village Drainage Ditch Improvements Only We have reviewed the above referenced project for compliance with the City of Coppell standards and offer the following coed,htS. Type "Y" inlet at STA. 1+52 is presently undersized for a 72" diameter pipe connection. A minimum 9' x 9' outside wall dimensions are recon~nended. 2. Sho~ construction details for type "Y" and "S" inlets and also for the Junction box. 3. Locate Junction box directly eastward from existing box culvert and make tie-in. Keep grate inlet at low point and tie into system. 4. Base flows on q50 not Q25 (Technica~ Paper #&0). 5. Keep velocity in 18" diameter RCPLateral 12.5 fps or less (if possible). 6. Ne~Property ditch line - add note - "grade to drain," sho~ns flow arrow~. If you have any questions concerning any of the above, please contact Kevin Peiffer at GINN, iNC., 386-6611. H. Wayne Oinn, P.E. cc: Steve Corem l~aA End,ne,rs 16135 Preston Road · Suite 106 · Dallas. Texas 75248 · Phone 214/386-6611