Loading...
Hooptown-CS000921 CITY OF COPP~L PLANNING DEPARTMENT STAFF REPORT CASE: HOOPTOWN LOTS 1 & BLOCK PRELIMINARY PLAT P & Z HEARING DATE: September 21, 2000 C.C. HEARING DATE: October 10, 2000 LOCATION: Along the south side of E. Beltline Road, approximately 1,700 feet east of MacArthur Boulevard. SIZE OF AREA: Approximately 27.063 acres of property. CURRENT ZONING: LI (Light Industrial). REQUEST: Preliminary Plat approval for Hooptown. APPLICANT: Applicant: Surveyor: Hooptown, LLC Survcon, Incorporated 708 South College St., Suite 209 251 O'Connor Ridge Blvd. McKinney, Texas 75069 Suite 200 (214) 544-2300 Farmers Branch, Texas 75229 Fax: (214) 544-2302 (972) 541-0741 Fax: (972) 541-0762 HISTORY: There has been no platting history on this tract of land. TRANSPORTATION: East Belt Line Road is proposed to be a P6D, 6 lane divided major thoroughfare built within a 120' wide right-of-way. Construction is scheduled for fourth quarter this year. SURROUNDING LAND USE & ZONING: North- Railroad, Creekview Addition "SF-9-PD" South - North Lake, City of Dallas East - TXU Electric & Gas Right-of-Way, vacant"LF' Light Industrial West - Vacant, Shake & Shingle, "LF' Light Industrial Item# 7 COMPREHENSIVE PLAN: The Comprehensive Plan shows the property as suitable for light industrial/showroom uses. DISCUSSION: This property has never been platted. The purpose of this request is to plat both Lots 1 & 2 of Block A. Lot 1 will contain approximately 17.063 acres and is proposed to be developed with a basketball/recreation facility. Lot 2 will contain approximately 10 acres and its proposed use is not known at this time. The preliminary plat shows all required setbacks, fire lane easements, and one public sanitary sewer easement. All other storm sewer easements on-site are private and not indicated on the plat. The preliminary plat is deficient in that the radius within the Fire Lanes is not designed to City of Coppell standards. Staff has recommended that the applicant revise the deficient turning radius; it is not believed to significantly impact the proposed layout of the site. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff is recommending APPROVAL of the preliminary plat for Lots 1 & 2, Block A Hooptown subject to the following conditions: 1) All turning radius on fire lanes shall measure a minimum of 30~ on the inside and 54" on the outside. ALTERNATIVES: 1) Recommend approval of the request. 2) Recommend disapproval of the request 3) Recommend modification of the request ATTACHMENTS: 1) Preliminary Plat (Cover sheet of site plan package) Item # 7