IAAM-LR 990729 REPORT OF FIELD
COMPACTION
TESTS
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE 7/29/99
SOUTHLAKE, TEXAS
PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-8
COPPELLo TEXAS
TEST DATA:
TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATEDEPTH ~ NUMBER MOI$|URE DRY OEN~r¥ MOISTURE DRY DENSITY COMPACTION COMMENT*
% PCF % PCF
33 7/29/99 SG + 1.5 2 23.8 94.5 24,4 91 96 1-A
34 7/29/99 SG + 1.5 2 23.8 94.5 23.8 92 97' I-A
35 7/29/99 SG + 1.5 2 23.8 94.5 24.9 94 100 1-A
36 7/29/99 SG + 1.5 2 23.8 94.5 24.5 91 96 1-A
37 7/29/99 SG + 1.5 2 23.8 94.5 24.0 91 97 1-A
38 7/29/99 SG + 1.5 2 23.8 94.5 23.8 92 97 I-A
39 7/29/99 SG + 1.5 2 23.8 94.5 23.8 91 96 I-A
TEST LOCATION:
33 PARKING AREA - 25' SOUTH AND 50' WEST OF NORTHEAST CORNER
34 PARKING AREA - 75' SOUTH AND 50' WEST OF NORTHEAST CORNER
35 PARKING AREA -125' SOUTH AND 50' WEST OF NORTHEAST CORNER
36 PARKING AREA - 175' SOUTH AND 50' WEST OF NORTHEAST CORNER
37 PARKING AREA - 225' SOUTH AND 50' WEST OF NORTHEAST CORNER
38 PARKING AREA - 275' SOUTH AND 50' WEST OF NORTHEAST CORNER
39 PARKING AREA - 325' SOUTH AND 50' WEST OF NORTHEAST CORNER ~ ~ ~..
NA IURAI S~JRGRAD~ B P[RCEN1 COMPACTION ODES NOT COMPLY WITH SPECIFICATIONS