Loading...
IAAM-LR 990729 (6) REPORT OF FIELD COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 ~ Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE 7/29/99 SOUTHLAKE, TEXAS PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-9B COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL I~) OPTIMUM MAXIMUM LAB IN PLACE iN PLACI: PERCENT NO. DATEDEPTH "~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT % PCF % PCF 63 7/29/99 SG + 1.0 2 23.8 94.5 26.2 92 97 1-A 64 7/29/99 SG + 1.0 2 23.8 94.5 24.6 93 98' I-A TEST LOCATION: 63 PARKING AREA - 325' SOUTH AND 150' WEST OF NORTHEAST CORNER 64 PARKING AREA - 375' SOUTH AND 150' WEST OF NORTHEAST CORNER I FILl e A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICA LIONS 2 NATURAL SUBGRAOE B. PERCENT COMPACTION DOES NO] COMPLY WITH SPECIFICATIONS 3 lIME SIA~ILIZED C PERCEN1 IN PLACE MOISTUR£ DO£S NOT COMPLY WITH SPECIFICATIONS 4 CEMEN! TREA[£O O RETESl Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting