IAAM-LR 990729 (6) REPORT OF FIELD
COMPACTION
TESTS
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100 ~
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE 7/29/99
SOUTHLAKE, TEXAS
PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-9B
COPPELL, TEXAS
TEST DATA:
TEST ~ ELEV. SOIL I~) OPTIMUM MAXIMUM LAB IN PLACE iN PLACI: PERCENT
NO. DATEDEPTH "~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT
% PCF % PCF
63 7/29/99 SG + 1.0 2 23.8 94.5 26.2 92 97 1-A
64 7/29/99 SG + 1.0 2 23.8 94.5 24.6 93 98' I-A
TEST LOCATION:
63 PARKING AREA - 325' SOUTH AND 150' WEST OF NORTHEAST CORNER
64 PARKING AREA - 375' SOUTH AND 150' WEST OF NORTHEAST CORNER
I FILl e A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICA LIONS
2 NATURAL SUBGRAOE B. PERCENT COMPACTION DOES NO] COMPLY WITH SPECIFICATIONS
3 lIME SIA~ILIZED C PERCEN1 IN PLACE MOISTUR£ DO£S NOT COMPLY WITH SPECIFICATIONS
4 CEMEN! TREA[£O O RETESl
Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting