Loading...
IAAM-LR 990727REPORT OF FIELD ALPHA TESTING, INC. COMPACTION TESTS 2209 Wisconsin St., Suite 100 ~ Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE 7/27199 SOUTHLAKE, TEXAS PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-4 COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPTH "~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DEN~TY COMPACTION COMMENT' % PC~ % PC~: 1 7/27/99 SG 1 27.0 90 28.7 87 97 2-A 2 7/27/99 SG 1 27.0 90 27.6 88 98 ' 2-A 3 7/27/99 SG 1 27.0 90 29.0 86 95 2-A 4 7/27/99 SG 1 27.0 90 27.6 89 99 2-A 5 7/27/99 SG 1 27.0 90 27.9 88 98 2-A 6 7/27/99 SG 1 27.0 90 29.0 87 97 2-A 7 7/27/99 SG 1 27.0 90 27.5 89 99 2-A TEST LOCATION: 1 PARKING AREA - 25' SOUTH AND 50' WEST OF NORTHEAST CORNER 2 PARKING AREA - 75' SOUTH AND 50' WEST OF NORTHEAST CORNER 3 PARKING AREA -125' SOUTH AND 50' WEST OF NORTHEAST CORNER 4 PARKING AREA - 175' SOUTH AND 50' WEST OF NORTHEAST CORNER 5 PARKING AREA - 225' SOUTH AND 50' WEST OF NORTHEAST CORNER 6 PARKING AREA - 275' SOUTH AND 50' WEST OF NORTHEAST CORNER 7 PARKING AREA - 325' SOUTH AND 50' WEST OF NORTHEAST CORNER 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOr COMPLY WITH SPECIFICATIONS 3 I IMt ,~1AI~III,,'ED C PERCEN[ IN PLACE MOISIURE DOES NO[ COMP1. Y WITH SPECIFICA[IONS 4 CEMEN[ [REAl'ED D. RETES! ~EST~t~:,~~. Geotechnical Engineering · Conslrucffon Materials Testing · Environmental Engineering · Consutting