Loading...
Gunner P2-CS000126 (3) Carson-Salcedo-McWilliams, Inc. CONSULTING CIVIL ENGINEERS - LAND SURVEYORS DALLAS FORT WORTH Rlchalrd Calraon, Jr., P.E. E,t~cut/v~ I~ce - Pre~ld~g.~t Mac McWIIll~m~, P.E. 2000-01-26 City of Coppell Engineering Department P.O. Box 478 Coppell, Texas, 75019 Attention: Mr. Kent Collins, P.E. Civil Engineer Subject: 971146- GUNNER SUBDIVISION- PHASE H LOT2, BLOCK A Dear Mr. Collins: Enclosed, please find a copy of your letter dated December 20, 1999. The comments stated in this letter have been addressed and are being submitted for a second review. Should you require any additional information, please contact the undersigned at your convenience. Sincerely, Carson, Salcedo, McWilliams, Inc. Stephanie Laughlin, EIT 1201 MAIN STREET, SUITE 1530 DAI. J.AS, TEXAS 75202 (214) 741-4640 FAX (214) 741-4610 http:/Iw~nv.csm, net.corn RO. Box 478 Coppeil. Texas 75019 972-462-OO22 The City With A Beautiful Future RO. BOX 478 COPPELL. TEXAS 75019 December 20, 1999 B. McWilliams, Jr., P.E. Carson Salcedo McWilliams, Inc. 1201 Main Street, Suite 1530 Dallas, Texas 75202 RE: Gunner Subdivision, Lot 2, Block A Dear Mr. McWilliams: The City of Coppell has reviewed the referenced plans and has the following comments to offer: 1. On the Plat, label the 24'-wide fire lane and reference the FEMA map for the floodplain limit location. 2. On the paving plan, locate the 8'-wide brick paver band one foot inside the property line. 3. All work adjacent to Belt Line Road needs to be completed between 9am and 4pm. 4. Indicate on the plans whether the 5' sidewalk is existing or will be constructed with this project. 5. You need a letter of permission from the Irving Flood Control District to encroach into their drainage easement with the dumpster pad or parking areas. 6. Use City Standard Details for all applicable items. 7. Remove the 'Typical Building Section' detail from the civil plans. 8. You will need an approved floodplain development permit prior to doing any work within the 100-year floodplain. 9. The City of Coppell Subdivision Ordinance requires all storm drain be RCP with a minimum diameter of 18". This requirement needs to be met for all storm drain located in an easement. However, you may submit a letter to the City Engineer requesting permission to use ADS pipe for private storm drain lines. 10. On the profiles, show either the hydraulic grade line or indicate that the pipe is in partial flow. 11. The proposed water meters for the project need to be combination fire/domestic meters as required by the City Utility Department. 12. Please consult the City Fire Department regarding the need to loop the fire line at the southeastern portion of the property. 13. The minimum grade for an 8" sanitary sewer is 0.34%. Also, note that any sanitary sewer manhole deeper than 12.5' needs to be 5' in diameter. 14. Show all utility crossings on the sanitary sewer profiles. Note that all crossings need 2' minimum clearance or concrete encasing. There are various other minor comments throughout the plans. When all comments have been addressed, please return these marked plans and two sets of revised plans to the City for review. If you have any questions, please contact me at (972) 304-7019. Sincerely, Kent M. Collins, P.E. Civil Engineer