Hager Container-CS 880511 · COPPELL FIRE DEPARTMENT MEMO TO: Larry Jackson - City Attorney FROM: Jackie R. Mayfield - Fire Chief DATE: May 11, 1988 SUBJECT: Fire Lanes for the Proposed Hagar Box Company The City of Coppell Code of Ordinances Section 15-5-5 with Exhibits 15-I, 15-2, 15-3, and 15-4 describe the criteria for lanes as required by the Hagar Box Company. The UniX'otto Fire Code, 1985 Edition, Section 10207 further outlines the provision of the requirements for fire apparatus access roads. Basic descriptions of the code are: I. 24' wide 2. All weather surface 3. All parts of the building(s) must be within 150' of a fire lane 4. If a fire lane is over 150' long and is not connecting with an approved exit lane, then the fire lane must have a turn around that conforms to Exhibit 15-4 5. Copies of the Code and exhibits are attached. cc: Alan D. Ratliff - City Manager EXHIBIT'IA" Sec. 15-5-5 FI~,.B LANI~S A. When part of the private road is selected as a fire lane by the '~-~' Fire Chief, or his authorized representative, it shall be marked along the perimeter with conspicuous signs in accordance with the specifications shown on Exhibits 15-! and 15-2, and where a curb exists, the sign sha~l bare the words "FIRE LANE - NO PARKING" painted: 1. in four inch high letters - white in color; (Ord. 86-357) 2. at 15 foot intervals; (Ord. 86-357) 3. on a contrasting background stripe - red in color, six inches wide; (Ord. 86-357) B. Shall be free of all obstructions which pose a substantial threat of interference .to Fire Department, fire fighting or rescue activities. (Ord. 86-357) C. Shall be constructed in accordance with the specifications set out in Exhibits 15-3 and 15-4 and shall be surfaced with a material substantial to support any Fire Department vehicle. (Ord. 86-357) D. Shall be maintained so that it remains structurally unaffected during inclement weather. (Ord. 86-357) E. The operator of premises shall maintain, free of obstruction, all fire lanes on his premises. (Ord. 86-357) F. No .person may mark, post, or otherwise identify a non-fire lane, private vehicular passageway: 1. as a fire lane; or (Ord. 86-357) 2. in such a manner as tends to create confusion as to whether the passageway is a fire lane. (Ord. 86-357) O. No person may park non-emergency vehicles in a fire lane. (Ord. 86-357) H. An unauthorized vehicle in a fire lane is: 1. subject to removal by the operator of the premises, with the expense of removal and storage to be borne by the registered owner of the vehicle; (Ord. 86-357) 2. subject to citation, as well as removal, by. the Fire Chief, his authorized representative, or a peliee officer; (Ord. 86- 357) 3. prima faeie evidence that the person in whose name tl~e' -. vehicle is registered is the person who parked the vehicle in .. the fire lane. (Ord. 86-357) Revised 9/87 Chapter 15, Page 16 FIRE. LANE NO PARKING - 'FIRE LANE. 'NO PARKING '-_ 'DNi)IUVd' "ON ' ]NV'i ~11~1:~'~-. .. 9NI'!,IUVd." "}'IRE LANE NO PARKING' ~ BE PAINTED ~TIR~ ~G~ O~ D~D~CAT~ : ~ERE P~I~L~ ALL FIRE ~E ~RKINGS S~LL BE E~UIR~ ~ BE ~C~ ~ THE C~. ~t~ TH~ A~VE FIRE ~E ~RKI~GS AR~ D~E~IN~ ~ BE IN~UAT~ IN CO~TROLLiNG T~FF~C. TH~ PROP~ O~ WILL BE R~U~R~ ~ ~ST FIRE OTHER FIRE ~E ~KINGS. ~t~ RESTRIPiNG. ~D~ONS ~ THE ~I~TING FIRE ~ES ARE N~ A%~WED WITHOUT PRIOR APPROVAL OF THE F~RE DEP~T~T. Exhibit 15-1 Specifications foL- Fh'e Lane MarkinE Revised 9/8? Chapter 15, Page I FiR I -- , L A N E PARKING/ GROUt;D LEV E'- - Exhibit 15-2 Speeifi~fi~ fo~ l~ire Lane Signs Revised 9/87 Chapter 15, Page 19 CONSTRUCTION SPECIFICATIONS POR FIRE LANES 1. Construction - Fire lanes shall be constructed of an all-weather driving surface having a capability to support a 40,000 pound vehicle. 2. Width - Fire lanes shall be a minimum of 24 feet in width. 3. Height - A minimum of 14 feet of clear height shall be available above all fire lanes. 4. Dead-ends - Dead-end fire lanes shall not exceedS50 feet. 5. Turn-arounds - When it is not possible to connect a fire lane at both ends to a dedicated street, approved turn-around installations shall be provided. For approved fire lane turn-arounds, see "Illustration 1." 6. Turn radius - All fire lane turns shall have a 30-foot inside radius and 50-foot outside radius. 7. Markings - Markings approved by the Building Official or the Fire Chief or his authorized representative shall be posted in conspicuous places along fire lanes stating "Fire Lane - blo Parking." Exhibit 15-3 Revised 9/87 Chapter 15, Page 20 F"I t~. $ FIG. F..Mlibit 15--4 Permi.~ible l~ire Lame 'l'urnm~unds Revised 9/87 chapter 15, Page 21