Loading...
IAAM-LR 990823 (2) REPORT OF FIELD ALPHA rESTING, INC. COMPACTION TESTS 2209 Wisconsin St., Suite I00 Dallas, Texas 75229 ~ 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE 8/23/99 SOUTHLAKE, TEXAS PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-24A COPPELL, TEXAS TEST DATA: TEST SOIL ID OPTIMUM MAXIMUM LAB tN PLACE IN PLACE PERCENT NO. DATE NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 166 8/23/99 FG-2.3 3 23.8 94.5 24.5 91 97 1-A 167 8/23/99 FG-1.7 3 23.8 94.5 25.4 91 96 1-A 168 8/23/99 FG-1.0 3 23.8 94.5 25.3 91 97 1-A 169 8/23/99 FG-0.3 3 23.8 94.5 23.8 92 97 1-A 170 8/23/99 FG 3 23.8 94.5 23.9 93 98 1-A 171 8/23/99 FG-2.7 1 27,0 90 30.0 86 96 1-A 172 8/23/99 FG-2.0 1 27.0 90 29.5 88 97 1 -A TEST LOCATION: 166 8" WATER LINE 25' SOUTH AND 47' EAST OF SOUTHWEST CORNER OF BUILDING PAD 167 8" WATER LINE 25' SOUTH AND 49' EAST OF SOUTHWEST CORNER OF BUILDING PAD 168 8" WATER LINE 25' SOUTH AND 50' EAST OF SOUTHWEST CORNER OF BUILDING PAD 169 8" WATER LINE 25' SOUTH AND 52' EAST OF SOUTHWEST CORNER OF BUILDING PAD 170 8" WATER LINE 25' SOUTH AND 55' EAST OF SOUTHWEST CORNER OF BUILDING PAD 171 8" WATER LINE 45' EAST AND 25' NORTH OF SOUTHEAST CORNER OF BUILDING PAD 172 8" WATER LINE 45' EAST AND 27' NORTH OF SOUTHEAST CORNER OF BUILDING PAD 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2, NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Respec~ 3 LIME STARILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4 CEMENT TREATED D. RETEST ' ALPH~z~S~f~IG, INC. / GeoteChnical Engineering · Construction Materials Testing · Environmental Engineering · Consutflhg