Loading...
IAAM-LR 990823 REPORT OF FIELD ALPHA TESTING, INC. COMPACTION TESTS 2209 Wisconsin St., Suite I00 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) ~ FAX: 972/406-8023 TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE 8/23/99 SOUTHLAKE, TEXAS PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-24 COPPELL, TEXAS TEST DATA: TEST . SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE NUMBER MOISTURE DRY DENSITY MOISTURE DrY DENSITY COMPACTION COMMENT* ~ ~ ~=m~==~,,~ ~,,~==,m~.m~,~,~ ~ PCF % PCF 159 8/23/99 FG-3.0 1 27.0 90 30.0 86 95 1-A 160 8/23/99 FG-2.3 1 27.0 90 28.5 88 98 1-A 161 8/23/99 FG-1.7 1 27.0 90 28.6 88 98 1-A 162 8/23/99 FG-1.0 1 27.0 90 27.0 86 95 1-A 163 8/23/99 FG-0.3 1 27.0 90 28.9 87 97 1-A 164 8/23/99 FG 3 23.8 94.5 24.4 93 98 1 -A 165 8/23/99 FG-3.0 3 23.8 94.5 24.3 91 97 1-A TEST LOCATION: 159 STORM SEWER LINE B AT STATION #1+50 16____~0 STORM SEWER LINE B AT STATION #1+52 161 STORM SEWER LINE B AT STATION #1+55 162 STORM SEWER LINE B AT STATION #1+57 16~3 STORM SEWER LINE B AT STATION #1+59 16~4 STORM SEWER LINE B AT STATION #1+60 165 8" WATER LINE 25' SOUTH AND 45' EAST OF SOUTHWEST CORNER OF BUILDING PAD FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~~~Y~.~ e d LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS CEMENT TREATED D. RETEST ' "ALP~FE , INC. Geotechnical Engineering · Construc#bn Materials Testing · Environmental Engineering · Consulflhg