Loading...
IAAM-LR 990816REPORT OF FIELD ALPHA rESTING, INC. COMPACTION TESTS 2209 Wisconsin St., Suite 100 ~ Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE 8/16/99 SOUTHLAKE, TEXAS PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-22 COPPELL, TEXAS TEST DATA: TEST D '~"~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEEPTH ~ NUMBER MOISTURE DRY DENSITY MOISTURE [JRY DENSITY COMPACi'tON COMMENT % PCF % PCF 139 8/16/99 FG-1.5 4- 12.7 113.8 14.2 112 98 1-A 140 8/16/99 FG-1.0 4. 12.7 113.8 14.8 110 97 ' 1-A 141 8/16/99 FG-0.5 4 12.7 113.8 14.7 111 97 I-A 142 8/16/99 FG 4 12.7 113.8 15.1 110 97 I-A 143 8/16/99 FG-1.5 4 12.7 113.8 14.7 110 97 1-A 144 8/16/99 FG-I.0 4 12.7 113.8 14.7 I 11 98 I-A 145 8/16/99 FG-0.5 4 12.7 113.8 14.8 110 97 1 -A TEST LOCATION: 139 BUILDING PAD - 30' WEST AND 20' SOUTH OF NORTHEAST CORNER 140 BUILDING PAD 30' WEST A,%~D 20' SOUTH OF NORTHEAST CORNER 14.1 BUILDING PAD - 30' WEST AND 20' SOUTH OF NORTHEAST CORNER 142 BUILDING PAD - 30' WEST AND 20' SOUTH OF NORTHEAST CORNER 14.3 BUILDING PAD - 30' WEST AND 60' SOUTH OF NORTHEAST CORNER 144 BUILDING PAD - 30' WEST AND 60' SOUTH OF NORTHEAST CORNER 145 BUILDING PAD - 30' WEST AND 60' SOUTH OF NORTHEAST CORNER 1. FILL ~' A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUSGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICAIIONS Respec~ 5. LIME SIABILIZED C, PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREA[ED D. RETEST Geatechnical Engineering · Construction Mcrterials Testing · Environmental Engineering · Consulting