IAAM-LR 990813 REPORT OF FIELD
COMPACTION
TESTS
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-89 ! 1 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE 8/13/99
SOUTHLAKE, TEXAS
PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-21
COPPELL, TEXAS
TEST DATA:
TEST ~.. ELEV. SOIL tD OPTIMUM MAXIMUM LAB IN PLACe- IN PLACE F'ERCEN~
NO. DATEDEPTH ~ NUMBER MOISiURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT
123 8/13/99 FG-0.5 4 12.7 113.8 12.7 1 I 1 98 1-A
124 8113~99 FG 4 12.7 113.8 12.9 112 98 1-A
125 8/13199 FG-0.5 4 12.7 113.8 15.7 109 96 1-A
126 8/13/99 FG 4 12.7 113.8 13.5 109 96 1 -A
127 8113/99 FG-0.5 4 12.7 113.8 12.7 111 97 1-A
128 8/13/99 FG 4 12.7 113.8 13.5 113 99 1 -A
129 8/13/99 FG-0.5 4 12.7 113.8 12.8 111 98 1 -A
TEST LOCATION:
123 BUILDING PAD - 25' EAST AND 20' SOUTH OF NORTHWEST CORNER
124 BUILDING PAD - 25' EAST AND 20' SOUTH OF NORTHWEST CORNER
125 BUILDING PAD - 25' EAST AND 60' SOUTH OF NORTHWEST CORNER
126 BUILDING PAD - 25' EAST AND 60' SOUTH OF NORTHWEST CORNER
127 BUILDING PAD - 75' EAST AND 20' SOUTH OF NORTHWEST CORNER
128 BUILDING PAD - 75' EAST AND 20' SOUTH OF NORTHWEST CORNER
129 BUILDING PAD - 75' EAST AND 60' SOUTH OF NORTHWEST CORNER
Geotechnical Engineering · Construcflbn Materials Tes#ng · Environmental Engineering · Consutflhg