Loading...
IAAM-LR 990812 (3) REPORT OF FIELD ALPHA TESTING, INC. COMPACTION TESTS 2209 Wisconsin St., Suite 100 ~ Da//as, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE 8/12/99 SOUTHLAKE, TEXAS PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-20 COPPELL, TEXAS TEST DATA: TEST ~"~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE iN PLACE PERCENI NO. DATEDEPTH "'~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT * % PCF % PCF 115 8/12/99 FG- 1.5 4 12.7 113.8 15.1 109 96 1 -A 118 8/12/99 FG-1.5 4 12.7 113.8 14.2 110 97 1 -A 120 8/12/99 FG-1.0 4 12.7 113.8 13.9 112 98 1-A 121 8/12~99 FG- 1.0 4 12.7 113.8 13.5 112 98 1 -A TEST LOCATION: 115 BUILDING PAD - 30' EAST AND 20' SOUTH OF NORTHWEST CORNER 116 BUILDING PAD - 30" EAST AND 60' SOUTH OF NORTHWEST CORNER 117 BUILDING PAD - 70' EAST AND 20' SOUTH OF NORTHWEST CORNER 118 BUILDING PAD - 70' EAST AND 60' SOUTH OF NORTHWEST CORNER 119 :BUILDING PAD - 30' EAST AND 20' SOUTH OF NORTHWEST CORNER 120 BUILDING PAD - 30' EAST AND 60' SOUTH OF NORTHWEST CORNER 121 BUILDING PAD - 70' EAST AND 20' SOUTH OF NORTHWEST CORNER I [:ILl * A. IN PLACE PERCENT MOISIURE AND PERCENT COMPACTION COMPLY WITH SPECIFICAIIONS 2. NATURAL SUBGRAD£ B. PERCENt COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ReSD~'~~ 3. LIME SiABILIZED C PERCEN1 IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4 CEM£NI ~REATED U HEIESI Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting