Loading...
IAAM-LR 990731 (2) REPORT OF FIELD COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St., Suit~ 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE 7/31/99 SOUTHLAKE, TEXAS PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-12 COPPELL, TEXAS TEST DATA: , TEST , SOIL ID OPTIMUM MAXIMUM LAR IN PLACE IN PLACE PERCENT NO. DATE NUMBER MOISTURE DRY DENSITY MOISTURE: DRY DENSITY COMPACTION COMMENT' % PCF % PCF 79 7/31/99 FG 2 23.8 94.5 25.3 90 96 1-A 80 7/31/99 FG 2 , 23.8 94.5 24.2 91 97' 1 -A 81 7/31/99 SG I 27.0 90 27.3 89 98 2-A 82 7/31/99 FG 2 23.8 94.5' 25.4 90 96 1 -A 83 7/31/99 SG 1 . 27.0 90 29.9 88 98 2-A 84 7/31/99 FG 2 23.8 94.5 25.2 91 96 1 -A 85 7/31/99 SG · 1, 27.0 90 27.9 90 100 2-A TEST LOCATION: 79 PARKING AREA -325' SOUTH AND 150' WEST OF NORTHEAST CORNER 80 PARKING AREA - 375' SOUTH AND 150' WEST OF NORTHEAST CORNER 81 BUILDING PAD - 20' SOUTH AND 20' WEST OF NORTHEAST CORNER 82 BUILDING PAD - 2.0' SOUTH AND 20' WEST OF NORTHEAST CORNER 83 BUILDING PAD - 20' SOUTH AND 70' WEST OF NORTHEAST CORNER 84 BUILDING PAD - 20' SOUTH AND 70' WEST OF NORTHEAST CORNER 1 FIlL ~ A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS~~7/////~ 2 NA IURA[ SUSGRADE B. PERCEN1 COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~ly, ' mitred 3 lIME: SIARtLIZ[:D C PERCEN1 IN PI. ACE: MOISTURE DOES NOT COMPtY WITH SPECIFICATIONS 4 CEMENI IREA[ED U. RE[ESI Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting