Loading...
IAAM-LR 990730REPORT OF FIELD ALPHA TESTING, INC. COMPACTION TESTS 2209 Wisconsin St,, Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE 7/30/99 SOUTHLAKE, TEXAS PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-10 COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO, DATE DEPTH ~ NUMBER ~O~SZURE DRY 0ENSITY MOISTURE DRY DENSITY COMPACi'ION COMMENT* % PCF % PCF 65 7/30/99 FG 2 23.8 94.5 24.8 89 94 1-B 66 7/30/99 FG 2 23.8 94.5 25.4 90 95' 1-A 67 7/30/99 FG 2 23.8 94.5 25.4 90 95 1 -A 68 7130/99 FG 2 23.8 94.5 25.1 91 96 1 -A 69 7/30/99 FG 2 23.8 94.5 25.1 90 96 I-A 70 7/30/99 FG 2 23.8 94.5 24.9 91 96 I-A 71 7/30/99 FG 2 23.8 94.5 24.0 92 97 I-A TEST LOCATION: 65 PARKING AREA - 25' SOUTH AND 50' WEST OF NORTHEAST CORNER 66 PARKING AREA - 75' SOUTH AND 50' WEST OF NORTHEAST CORNER 67 PARKING AREA -125' SOUTH AND 50' WEST OF NORTHEAST CORNER 68 PARKING AREA - 175' SOUTH AND 50' WEST OF NORTHEAST CORNER 69 PARKING AREA - 225' SOUTH AND 50' WEST OF NORTHEAST CORNER 70 PARKING AREA - 275' SOUTH AND 50' WEST OF NORTHEAST CORNER 71 PARKING AREA - 325' SOUTH AND 50' WEST OF NORTHEAST CORNER fl ~ .,,~ · NATURAL SUSGRAD£ B. PERCENT COMPACTION DOES NO! COMPLY WITH SPECIFICATIONS LIME SIABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS CEMENT TREATED O. RETEST ~/I~N~, tR Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting