IAAM-LR 991002 (3) REPORT OF CONCRETE
ALPHA TESTING, INC. COMPRESSION .... .,.,
2209 Wisconsin St., ,~uite I00
Dallas, Texas 75229 NOV ]. 5 Jg-9.g
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023 FRAN~, L.
C,,ONSTRU~T~
TESTED FOR: FRANK DALE CONSTRUCTION, /NC. DATE OF ISSUE: 10/02/99
SOUTHLAKE, TEXAS
PROJECT: IAAM HEADQUARTERS BUILDING OUR REPORT NO.: 99571-79
COPPELL, TEXAS
FIELD DATA
LOCATION OF CONCRETE PLACEMENT FLOOR SLAB: 16' EAST & 20' NORTH OF SW CORNER OF BUILDING SLAB
DATE PLACED 10/02/99 PLANT N/A
T~ME 15:45 DEMVER TICKET NO. 3444
SLUMP (ASTM C-143) 4.5 MIX PROPORTIONS (SSD)
AIR CONTENT (ASTM C-231 [] OR C-173 []) N/A CEMENT NIA
AIR TEMPERATURE 96 WATER N/A
CONCREI'F_ TEMPERATURE 92 FINE AGGREGATE N/A
DATE RECEIVED 10/04199 COARSE AGGREGATE N/A
FIELD DATA SUBMITTED lay KALU ADMIXTURE N/A
MIX DATA SUBMITTED aY OSBORN/
SPECIMENS CAPPED IN aCCORDANCE WITH ASTM C-617
COMPRESSION TEST RESULTS [~'/'Cylinders made by ALPHA
(NOMINAL CYLINDER SIZE $" X 12") representative.
(ASTM C-39) ~ Cylinders made byArchitecrs
, o~ Cont~acto¢~ fe~'e~entati~e.
I
I
LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE ~'~inders picked up by ALPHA
NO. CURING TESTED DAYS LOAD STRENGTH, PSI laboratory,
149 LAB 10/09/99 7 79,409 28,27 2,8t 0 [] Cylinders delivered to ALPHA
150 LAB 10/30199 28 105,256 28.27 3,720 /'~ laboratory.
151 LAB 10/30/99 28 107,362 28.27 3,800[2~Compression tesl results comply with
152 LAB HOLD H 28.27 applicable specificalions.
C~ Comp~'ess. ion test results cio not comply
with applicable specifications.
Specifications 28 3,500
REMARKS: ALPHA TESTING, INC/
Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting