Loading...
IAAM-LR 991230 (2) REPORT OF CONCRETE COMPRESSION TEST ALPHA TESTING, INC. 220g Wisconsin St., SuiteDallas, Fexos 75229 100 RECEIVED 972/620-8911 - 972/263-493 7 (Metro) FAX: 972/406-8023 _ .FFJANK DALE TESTED FOR: FRANK DALE CONSTRL/CT~INC,./.. DATE OF ~SSLIE: 12/30/99 SOUTHLAKE, TEXAS c't:~THUCTION, INC. PROJECT: IAAM HEADQUARTERS BUILDING OUR REPORT NO.: 99571-105 COPPELL, TEXAS FIELD DATA LOCATION OF CONCRETE PLACEMENT SLAB EXTENSION: 8' EAST & 1' SOUTH OF SW CORNER OF SLAB DATE PLACED 12/30/99 PLANT 31 TIME 11:30 DELIVER TICKET NO. 1483214 SLUMP (ASTM C-143) 3 MIX PROPORTIONS AIR CONTENT {ASTM C-231 [] OR C-173 r'l) NIA CEMENT N/A AIR TEMPERATURE 69 WATER N/A CONCRETE TEI~PERATURE 74 FINE AGGREGATE N/A DATE RECEIVED 12/31/g9 COARSE AGGREGATE N/A FIELD DATA sugMrrrED BY S.C. ADMIXTURE N/A MIX DATA SUBMITTED BY TX[ SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 [] OR C-1231 COMPRESSION TEST RESULTS I.,J' C~tindem made by ALPHA (NOMINAL CYLINDER SIZE 6" X 12") represenlative. {ASTM C-39) ~1 Cylinders made by Architecrs or Contractor's represe*ntetive. LAB TYPE DATE AGE TOTAL I AREA COMPRESSIVE ~'~"~l--~iCylinders picked up by AL PHA NO. CURING TESTED DAYS LOAD STRENGTH, PSI 1 95 LAB 01/06/00 7 80,922 28.27 2,860 [] Cylinders delivered Io ALPHA 196 LAB 01127/00 2.8 28.27 laboralory. 197 LAB 01/27/00 28 28.27 [] Compression test results comply with 198 LAB HOLD H 28.27 applicable specifications. [] Compression test results do nol comply with applicable specif'malions. Specifications 28 3,500 Respectfulb/Submitted REMARKS: ALPHA TESTING, INC. Geotechnical Engineering · Consfrucfion Materials Testing · Environmental Engineering · Consulting