Loading...
IAAM-LR 991228 REPORT OF FIELD ALPHA TESTING, INC. COMPACTION TESTS Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/4068023 FRANK DALE TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE CONSTRCJ~, INC. SOUTHLAKE, TEXAS PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-104 COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE ORY DENSITY COMPACTION COMMENT* % PCF % PCF 202 12/28/99 FG 2 23.8 94.5 24.9 93 98 1-A 203 12/28/99 - FG 2 23.8 94.5 24.4 91 97 1-A 204 12/28/99 FG 2 23.8 94.5 23.9 92 97 1-A 205 12/28/99 FG 2 23.8 94.5 24.2 91 96 1-A TEST LOCATION: 202 10' NORTH AND 2' WEST FROM SOUTHEAST CORNER OF BUILDING 203 i20' WEST AND 2' NORTH FROM SOUTHEAST CORNER OF BUILDING 204 120' WEST AND 2' NORTH FROM SOUTHEAST CORNER OF BUILDING 205 2' EAST AND 30' SOUTH FROM NORTHWEST CORNER OF BUILDING 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Res 3. LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS .. 4 CEMENT TREATED D RETEST ALPH~"~STING, INC, Geotechnical Engineering · Constructian Materials Testing · En~ronmenta/ Engineering · Consulting