IAAM-LR 991228 REPORT OF FIELD
ALPHA TESTING, INC. COMPACTION TESTS
Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/4068023
FRANK DALE
TESTED FOR FRANK DALE CONSTRUCTION, INC. DATE CONSTRCJ~, INC.
SOUTHLAKE, TEXAS
PROJECT IAAM HEADQUARTERS BUILDING OUR REPORT NO. 99571-104
COPPELL, TEXAS
TEST DATA:
TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATEDEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE ORY DENSITY COMPACTION COMMENT*
% PCF % PCF
202 12/28/99 FG 2 23.8 94.5 24.9 93 98 1-A
203 12/28/99 - FG 2 23.8 94.5 24.4 91 97 1-A
204 12/28/99 FG 2 23.8 94.5 23.9 92 97 1-A
205 12/28/99 FG 2 23.8 94.5 24.2 91 96 1-A
TEST LOCATION:
202 10' NORTH AND 2' WEST FROM SOUTHEAST CORNER OF BUILDING
203 i20' WEST AND 2' NORTH FROM SOUTHEAST CORNER OF BUILDING
204 120' WEST AND 2' NORTH FROM SOUTHEAST CORNER OF BUILDING
205 2' EAST AND 30' SOUTH FROM NORTHWEST CORNER OF BUILDING
1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Res
3. LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ..
4 CEMENT TREATED D RETEST ALPH~"~STING, INC,
Geotechnical Engineering · Constructian Materials Testing · En~ronmenta/ Engineering · Consulting