Loading...
IAAM-LR 991021 (2) REPORT OF CONCRETE COMPRESSION TEST ALPHA TESTING, INC. 2209 Wisconsin St,, Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR: FRANK DALE CONSTRUCTION, INC. DATE OF iSSUE: 10/21/99 SOUTHLAKE, TEXAS PROJECT: IAAM HEADQUARTERS BUILDING OUR REPORT NO.' 99571-88 COPPELL, TEXAS FIELD DATA LOCATION OF CONCRETE PLACEMENT PANEL 2: 18' WEST & 6' NORTH OF SE CORNER OF PANEL DATE PLACED 10/21/99 PLANT 41 TIME 6:15 OEUVER TICKET NO, 1440753 SLUMP (ASTM C-143) ~' 4.75 MbX PROPORTIONS (SSD) AIR CONTENT (ASTM C-231 [] OR C-173[~ 5.5 CEMENT N/A AIR TEMPERATURE 50 WATER N/A CONCRETE TEMPERATURE 72 FINE AGGREGATE N/A DATE RECEIVED 110/22/99 COARSE AGGREGATE N/A FIELD DATA SUBMI'('~ t::O BY D.M, / ADMIXTURE N/A MIX DATA SUBMITTED BY TXJ / SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 [] OR C-1231 COMPRESSION TEST RESULTS J~" Cytindms mede by ALPHA (NOMINAL CYUNDER SIZE $' X 12') rel~esentative* (ASTM C-39) [] Cyfinders made by Axchltect's ./ o~ Co~tractof'~ ~e~'~sentative. LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE inders picked up by ALPHA NO. CURING TESTED DAYS LOAD STRENGTH, PSI laborato~/. 167 LAB 10/28199 7 90,303 28.27 3,190 [] Cyfindem delivered to ALPHA 168 LAB 11/18/99 28 119,896 28.27 4,240 169 LAB 11/18/99 28 118,743 28.27 4,200~¢v, Com~ess~n t~ r~sa,s comp~ w~h 170 LAB HOLD H 28.27 [] Cempms..~)n test results do no~ comply with applicable specifications. REMUS: DEC 0 8 1999 ?