Gulf Bearing-LR 951109 (2)TECHNOLOGIES INC _.laxim Tech.· Southwestern Labs 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 CLIENT: Gulf Bearing, Inc. Attn: Ross Ramsey 501 Industrial Blvd. Grapevine, TX 76051 PROJECT: Gulf Bearing Coppell, Texas REPORT OF CONCRETE COMPRESSIVE STRENGTH SERVICES: PROJECT NO.: 3200037 REPORT NO.: 32900A DATE OF SERV]CE: 10/27/95 AUTHORIZATION: ongoing REPORT DATE: 11/09/95 Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. CONTRACTOR: Rogers O'Brien CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 5" Max. AIR: N/A METHOD OF TEST: ASTM ¢-39 ASTM C- 143 PROJECT DATA CLASS OF CONCRETE: Mix Number 38 DATE OF PtACEMENT: 10/27/95 TIME SAMPtED: 10:00AM BY: Francisco Calvillo TEMPERATURE ('F) - AIR: 79 CONCRETE: 76 TRUCK NO: 574 TICKET NO: 7015416 AIR CONTENT(%): 3.0 LOCATION OF PLACEMENT: Paving north parking lot area. @ 40' North of building's northwest corner. CYLINDER MEASURED MARKED SLUMP DATE SET NO. (inches) TESTED 1 1 5.50 11/03/95 t 2 5.50 11/24/95 1 3 5.50 11/24/95 1 4 HOLD REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH (days) (in.) (sq.in.) (lbs. force) (psi) 7 6.00 28.27 90730 3210 28 6.00 28.27 109420 3870 28 6.00 28.27 115200 4070 HOLD REMARKS Technician: Francisco Calvillo Technician Started: 09:00AM Stopped: 03:00PM Report Of Tests Continued On Page 2 1001 LW Our fetters and reports .ere for the excl.us, ive u, se ofthe client.to whom they .are addressed _a.n~d__s_h~_/.n_o..t_,be ~e,~rlo~d~u~cr~ed~ne~C~e~nt~ir~m ful without the approval of the testl.n.g i,amora[pry.. ~n,e use o[ apply only to the sample tested an(=/or fnspec~ea, ano are no[ inQlcatlV~ Gulf Bearing, Inc. PROJECT NO. 3200037 DATE OF SERVICE: 10/27/95 REPORT NO. PAGE 2 SET NO. 2 32900A CONTRACTOR: Rogers O~Brien CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 5" Max. AIR: N/A METHOD OF TEST: ASTM C-39 ASTM C- 143 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) PROJECT DATA CLASS OF CONCRETE: Mix Number 38 DATE OF PLACEMENT: 10/27/95 TIME SAMPLED: 12:45PM BY: Francisco Calvillo TEMPERATURE ('F)-AIR: 80 CONCRETE: 78 TRUCK NO: 282 TICKET NO: 7015432 AIR CONTENT(%): 3,5 LOCATION OF PLACEMENT: Paving north parking lot. 78' North & 90~ west of buildings northeast corner. CYLINDER MEASURED MARKED SLUMP DATE SET NO, (inches) TESTED 2 1 5.00 11/03/95 2 2 5.00 11/24/95 2 3 5.00 11/24/95 2 4 HOLD REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM AGE DIAMETER AREA LOAD (days) (in.) (sq.in.) (lbs. force) COMPRESSIVE STRENGTH (psi) 7 6.00 28.27 98250 3470 28 6.00 28.27 121820 4310 28 6.00 28.27 120940 4280 HOLD REMARKS Technician: Francisco Calvillo Technician Started: 09:00AM Stopped: 03:00PM Report Of Tests Continued On Page 3 1001 LW Our letters and reports are for the exclusive use of the client .to whom they are addressed and shall not be reproduced except in full without the approva! of th.e .testl,n.g laboratpry; The use o[ ~uf,_n~_.m,.~_ m_.us.[_re_c.e.?.~e~,o_u_r ~v~ ~_e.n_.a~,r..oy~al;~O~',r I..e. tt~e~'mSil~d~rr~uOc~[ apply only to the sample testea aha/or inspec[ea, ana are no[ IrtQIC~TJV~ ol I.~1¢ q~.l~l~U[l~=~ u/ ¢UppQf~H~7 ~U~HU~ ~ a~ I~ · Gulf Bearing, Inc. PROJECT NO. 3200037 DATE OFSERVICE: 10/27/95 REPORT NO. PAGE 3 SET NO. 3 32900A CONTRACTOR: Rogers O'Brien CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 5" Max. AIR: N/A METHOD OF TEST: ASTM C-39 ASTM C- 143 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Cont i nued) PROJECT DATA CLASS OF CONCRETE: Mix Number 38 DATE OF PLACEMENT: 10/27/95 3qME SAMPLED: 02: 20PM BY: Francisco Calvillo TEMPERATURE ('Fl-AIR: 82 CONCRETE: 78 TRUCK NO: 572 TICKET NO: 7015440 AIR CONTENT(%): 3.3 LOCATION OF PLACEMENT: Paving @ firelane area 65' north & 18' west of buildings northwest corner CYLINDER MEASURED MARKED SLUMP DATE SET NO. (inches) TESTED 3 1 5.75 11/03/95 3 2 5.75 11/24/95 3 3 5.75 11/24/95 3 4 HOLD REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM ' COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH (days) (in.) (sq.in.) (lbs. force) (psi) REMARKS 7 6.00 28.27 89560 3170 28 6.00 28.27 110250 3900 28 6.00 28.27 109090 3860 HOLD Technician: Francisco Calvillo Technician Report Distribution: MAXIM TECH.eSO~WEj~,N LABS (1) GuLf Bearing, Inc. (1) Gro~atzky, Dupree & Associates (1) ltrockette, Davis, Drake (2) Rogers O'arien F. King Cook, P.E. (1) City of Coppett (1) City of Coppett 1001 LW Our letters and reports are for the excl,us, ive use ofthe client.to whom they ~are aqldressed .a~..d shall not ,be.[repr,o.d. uced ex. cept In. full without the approval of the testing ~aooratory,. I n.e use o! pu,r. na.m. e mvs~[ rece~v_e.~.op_r _wt. ~_e_n__a_p_p.,r..o¥~a~_.,_u~_,r apply only to the sample tested and/or inspected, ana are no; in~lca[lve oT[ne q~antme~ TECHNOLOGIES INC ..axim Tech. · Southwestern Labs 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 831-2700 FAX: (214) 920-1891 CLIENT: Gulf Bearing, Inc. Attn: Ross Ramsey 501 Industrial Blvd. Grapevine, TX 76051 PROJECT: Gulf Bearing Coppell, Texas REPORT OF CONCRETE cOMPRESSIVE STRENGTH SERVICES: PROJECT NO.: 3200037 REPORT NO.: 32738A DATE OF SERVICE: 10/25/95 AUTHORIZATION: ongoing REPORT DATE: 11/22/95 Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. CONTRACTOR: Rogers O'Brien CONCRETE SUPPLIER: Lattimore PLANT: N/A SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 5" max. AIR: N/A METHOO OF TEST: ASTM C-39 ASTM C-143 PROJECT DATA CLASS OF CONCRETE: (38) 3000 DATE OF PLACEMENT: 10/25/95 TIME SAMPLED: 08: 30AM BY: Francisco Calvillo TEMPERATURE ('F)-AIR: 59 CONCRETE: 70 TRUCK NO: 315 33CKET NO: 7015259 AIR CONTENT(%): 4.7 LOCATION OF PLACEMENT: Paving off southwest corner of building 35' south and 5' east CYLINDER MEASURED MARKED SLUMP DATE SET NO. (inches) TESTED 1 i 5.50 11/0~/95 1 2 5.50 11/22/95 Z 3 5.50 11/22/95 1 4 HOLD HOLD REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMEIER AREA LOAD STRENGTH (days) (in.) (sq.in.) (lbs. force) (psi) 7 6.00 28.27 99930 3530 28 6.00 28.27 124500 4400 28 6.00 28.27 124240 4390 REMARKS Technician: Francisco Calvillo Technician Started: 08:00AM Stopped: 02:00PM Report Of Tests Continued On Page 2 1001 LW Our letters and reports are for the excl.us, lve use ofthe client .to whom they ~re ad. dressed e.n.d shall not ,be fepr,od~uced ex~cept 19 full without the approv~ of ~e.testi~g ,amoratpry: In.e use o[ .ou~r, na.m,.~_ m_.us.[?_c?.?~e~,o_u_r _wr~ ~..e..n..a~p~pr..o~[ ger~se[mSilaarna~rr~dPuOc~[ apply only to the sample tes[ea ano/or inspe~ea, ana are not inolsa[iv~ ul UlC q~ltlLIc~ v/ {;~.~l~,/~lltl.· u~llu [~ ' Gulf Bearing, Inc. PROOEGT NO. 3200037 DATE OF SERVICE: 10./25/95 REPORT NO, PAGE 2 SET NO. 2 32738A CONTRACTOR: Rogers O'Brien CONCRETE SUPPLIER: Lattimore PLANT: N/A SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 5" max, AIR: N/A METHOD OF TEST: ASTM C-39 ASTM C-143 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) PROJECT DATA CLA. S8 OF CONCRETE: (38) 3000 DATE OF PLACEMENT: 10/25/95 TIME SAMPLED: ll:iOAM BY: Francisco Calvillo TEMPERATURE ('F)-AIR: 72 CONCRETE: 71 TRUCK NO: 573 TICKET NO: 7015278 AIR CONTENT(%): 4.2 LOCATION OF PLACEMENT: Paving @ north side of bldg. 25' north & 60' west of building's northeast corner CYLINDER MEASURED MARKED SLUMP DATE SET NO. (inches) TESTED 2 1 5.50 11/01/95 2 2 5.50 11/22/95 2 3 5.50 11/22/95 2 4 HOLD REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM AGE DIAMETER AREA LOAD (days) (in.) (sq.in.) (lbs. force) COMPRESSIVE STRENGTH (psi) 7 6.00 28.27 94800 3350 28 6.00 28.27 124480 4400 28 6.00 28.27 120190 4250 HOLD REMARKS Technician: Francisco Calvillo Technician Started: 08:00AM Stopped: 02:00PM Report Of Tests Continued On Page 3 1001 LW Our letters and reports are for the exclusive use of_the client .to wflom they .are aqldressed e.n.d shall not .be .[repr,o.d. uced ex. cept Iq fU without the approva of the testing laooratory,, inp use oT p ,,u[na~e m~s~ re_c. eLv~e~,o_u_r apply only to the sample tested and/or inspectea, an(3 are not in~caTJve oTme quamme~ o, ~pp~u~.uy ~u~.m.~. u~ ~,..,~. p~uu~.~ . Gulf Bearing, Inc. PROJECT NO. 3200037 DATE OF SERVICE: 10/25/95 REPORT NO. PAGE 3 SET NO. 3 32738A CONTRACTOR: Rogers O' Brien CONCRETE SUPPLIER: ~ttimore PLANT: N/A SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 5" max. AIR: N/A METHOD OF TEST: ASTM C-39 ASTM C- 143 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) PROJECT DATA CLASS OF CONCRETE: (38) 3000 DATE OF PLACEMENT: 10/25/95 TIME SAMPLED: 01: 25PM BY: Francisco Calvillo TEMPERATURE ('F)-AIR: 74 CONCRETE: 73 TRUCK NO: 572 llCKET NO: 7015301 AIR CONTENT(%): 3.9 LOCATION OF PLACEMENT: Paving @ northside of building 20' north & 75' east of building's northwest corner REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. (inches) TESTED (days) (in.) (sq.in.) (lbs. force) (psi) 3 1 5.00 11/01/95 7 6.00 28.27 91650 3240 3 2 5.00 11/22/95 28 6.00 28.27 122720 4340 3 3 5.00 11/22/95 28 6.00 28.27 129270 4570 3 4 HOLD HOLD REMARKS Technician: Francisco Calvillo Technician Started: 08:00AM Stopped: 02:00PM Report Distribution: MAXIM T~N LABS (1) Gulf Bearing, Ir~. (1) Grc~tzky, Dupree & Associates (1) Brockette, Davis, Brake (2) Rogers O'Brien (1) City of Coppe[[ ' (1) City of Coppe[[ 1001 LW Our le. ers a.d repo~s are for the exclusive use of the cllem to whom mey .are ad~essed a~ shall .ot ~11 .witho~ the approv~ of t~e_tesfl~g laborat9~: Th~ use o! p~na~e m~[ rece~ur _v~r. ~9__a~?~:v'~.~,_~_[ _~l~' -r-~u~s apply only to the sample testeo ano/or inspecteo, arlo are no[ iROlCallVe o? [ne quammes ol apparemly lUenu~ u[ =mllm ~ u .