Gulf Bearing-LR 951107TECHNOLOGIES INC Maxim Tech.* Southwestern Labs 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631-2700 FA~ (214) 920-1891 REPORT OF IN-PLACE DENSITY CUENT: Gulf Bearing, Inc. Attn: Ross Ramsey 501 Industrial Blvd. Grapevine, TX 76051 PROJECT: Gulf Bearing Coppell, Texas CLIENT NO.: 3200037 REPORT NO.: 32739 DATE OF SERVICE: 10/25/95 AUTHORIZATION: ongoing REPORT DATE: 11/07/95 SERVICES: Perform in-place density and moisture content tests to determine the degree of field compaction. CONTRACTOR: Rogers O'Brien TEST OF: Ramps on east side of building PROJECT DATA MATERIALS 23525-Dark brown clay MOISTURE/DENSITY RELATIONS OF~MUM MAXIMUM MOISTURE % DENSITY pcf 21.5 99.0 METHOD OF TEST: DENSITY: ASTM D2922 MOISTURE: ASTM D3017 SPECIFICATION DENSITY: 95% DRY DENSITY MOISTURE: _+ 2% opt moist REPORT OF TESTS FIELD OPTIMUM FIELD MAXIMUM TEST MOISTURE MOISTURE DENSR-Y DENS~'Y DENSITY NO LOCATION (%) (%) (Pcf) (Pcf) (% max) o Central ramp west half, below grade Central ramp east half, below grade 22.1 21.5 96.7 99.0 98 22.7 21.5 96.1 99.0 97 Test results on this report meet project specifications as noted above. ADDI~ONAL COMMENTS: Technician time recorded on report number 32738A Technician: Francisco Calvillo Technician Report Distribution: MAXIM TECH.e~OUTHWESTERN LABS (1) Gulf Bearing, ]nc. ~/"' /~' (1) Gromat:zky, Dupree & Associates (1) Brockette, Davis, Drake (2) Rogers O'8rien F. King Cook, P.E. (1) City of Col:peLt (1) City of Copper t 1007 LW Our letters and reports are for the exclusive use ofthe client .to whom they .are ad, dressed and shall not .be_repr.o,d. uced ex. cept in fu without the approval of the testing laboratory,, i n.e use o.1' pu,r. na.m, e m.us.~ rece~v_e~,o~u_r _v~r. F_e_n__a?~[9 ..v~:~,_u~_,r Le. tz_e/mS,,aa~rroedPuOc~~ apply only to the sample tested and/or inspecteQ, and are not indicative oT [tie quant[tie5 o, appetre,]uy lue[lu~ttl ur ~ .ma p . TECHNOLOGIES INC Maxim Tach.· Southwestern labs 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 CLIENT: PROJECT: SERVICES: Gulf Bearing, Inc. Attn: Ross Ramsey 501 Industrial Blvd. Grapevine, TX 76051 Gulf Bearing Coppell, Texas REPORT OF REINFORCING STEEL INSPECTION CLIENT NO.: 3200037 REPORT NO.: 32901 DATE OF SERVICE: 10/27/95 AUTHORIZATION: REPORT DATE: 11/06/95 Reinforcing steel inspection: REPORT OF TESTS On this date, reinforcing steel was observed for proper size, placement and alignment prior to concrete placement. The results of this inspection are attached and were furnished to the contractor at the time of inspection. Technician time recorded on report number 32900 Technician: Francisco Calvillo Technician Report Distribution: MAXIM TECH.,SOUTHWESTEF]~ LABS (1) Gulf Bearing, Inc. (1) Gromatzky, Dupree & Associates (1) Brockette, Davis, Drake (2) Rogers O'8rien F. King Co6k, P.E. (1) City of CoppeLL (1) City of CoppeLl 1099 LW Our letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced except in full without the approval of the testing laboratory. The use of ourname must receve our written approval. Our letters and reports apply only to the sample tested and/or inspecte~l, and are not indicative of the cluantities of apparent y dent ca or similar products. · .1UTHWESTERN LABORATORIES Materials, environmental and geotechnical engineering, nondestructive, metallurgical and analytical services 2575 Lone Star Drive · P.O. Box 224227, Dallas, Texas 75222 · 214/631-2700 REPORT OF REINFORCING STEEL INSPECTION CLIENT: PROJECT'. SERVICE: Perform reinforcing steel Client No.: 3 Z Report No.: ~¢ Date of Service: Page / of / inspection as detailed below. INSPECTION RESULTS Location~d Items Inspected:~ t~'~..,~,. ~)' ~b~) ~J~ EOt,~O/'~7½ O,~ S~ ~7~ ~ .... i ' ~ ~ /' ' ITEMS INSPECTED: CORRECT INCORRECT!ITEMS INSPECTED: CORRECT INCORRECT ITEMS INSPECTED: CORRECT INCORRECT Placing Drawings / Bar Length / Column Ties Properly Approved and Shape Tied and Spaced Bar Size &--"~ Proper Bar Placement /' Stirrup Spaclng/~pe Bar Grade ~ Properly Tied ~ Welded Splices Rebar Clean ~ Dowel Bars in Place,/ Mechanical Splices Form Clean / Proper Bar Supports / Proper Cover NO. of Bars -- ~J I ]Lapped Splices [ ~" I I I Discrepancies / Comments: ¢~~.~, /~/~ .~1. ,~--~,~/~.- , INC · TECHNOLOGIES INC Maxim Tech., Southwestern Labs 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631-2700 FAX~ (214) 920-1891 CLIENT: PROJECT: SERVICES: Gulf Bearing, Inc. Attn: Ross Ramsey 501 Industrial Blvd. Grapevine, TX 76051 Gulf Bearing Coppell, Texas REPORT OF PUNCH LIST ON NEW ROOF CLIENT NO.: 3200037 REPORT NO.: 32821 DATE OF SERVICE: 10/25/95 AUTHORIZATION: REPORT DATE: 11/06/95 Punch list on new roof: REPORT OF TESTS A brief roof inspection was performed on the recently applied single ply roof. The following items were found to be in need of completion or repair. (1) Patches required on some seams and scuppers locations. (2) Lap sealant to be applied on several flashing laps and boot laps. (3) Two air conditioning condensation lines were installed through the new roof and will require flashing. items and has The general contractor superintendent was made aware of these scheduled the roofers to make the needed repairs. Technician time: 2:30pm-5:O0pm Technician: Alan Spilles Report Distribution: MAXIM TECH.eSOU~WESI~R~I LABS (1) Gulf Bearing, [nc. (1) Gromatzky, Dupree & Associates (1) Brockette, Davis, Drake (Z) Rogers O'Brien F. King Cook, P.E. (1) City of Coppe[[ (1) City of Coppel,[ 1099 LW Our etters and reports are for the exclusive use of the client to whom they are addressed ~nd shall not ,be_reproduced ex. cept in f~ without the approval of the testing laboratory.. The use of. apply only to the sample tested and/or inspectecl, and are no[ inQicatlve Ol trl~ qumrluu~:= u/ ¢tpp~u¢l~uy ~u~Hu~.~ ~ ;,,m~, N,~ .