Gulf Bearing-LR 950918TECHNOLOGIES INC Maxim Tech. e Southwestern Labs 2575 Lone Star Dr. · P.O. Box 224227 Da~s. Texas 75222 Telephone: (214) 631~700 FAX: (214) g20-18g1 REPORT OF STRUCTURAL STEEL INSPECTION CUENT: Gulf Bearing, Inc. Attn: Ross Ramsey 501 Industrial Blvd. Grapevine, TX 76051 PROJECT: Gulf Bearing Coppell, Texas CLIENT NO.: 3200037 REPORT NO.: 25580 DATE OFSERVlCE: 9/18/95 AUTHORIZA~ON: Joe ~Thite REPORT DATE: 9/20/95 SERVICES: Perform structural steel inspection as detailed below. REPORT OF TESTS Drawings Utilized: Structural Steel Locations/Items Inspected Roof Level Framing Discrepancies/Co~ents: The following items were visually inspected at this time· 1. * Column anchor bolt; A to H and 1 to 5, not complete· * Joist seat welding; A to H and 1 to 5, all determined to be compliant with exception on line H-1 to H-5, not welded at .this time. Joist girder seat welding to column cap plates; A to H and 1 to 5, all determined to be compliant. * Joist bridging; A to H and i to 5, all determined to be compliant with exception on line A-1 to H-l, not attached to end wall (south) as detailed. Se Metal decking installation; A to D and i to 3.4, all screw attachments to supports and side laps were determined to be compliant. * Discrepancies Time: 8:30 am to 12:00 pm Technician: RandyWalcker NDE-Level II ~k~ Report Distribution: MAXIM TECH.~OU~WES,TERN LABS (1) Gulf Bearing, inc. (1) Gromatzky, Dupree & Associates (1) Brockette, Davis, Drake (2) Rogers O'Brien F. King Coo~, P.E. (1) City of Coppett Our letters and reports are for the excl,us, lva u. se ofthe client.to whom they .are ad, dressed a,n_d shall not_.be_r~pr.o_d~u_c_e~_e~Cree/~oJr~s full .wttho, ut the_approval of th.e .testl.n.g ~a. Dora~gry.. In9 use o! pu.r. na.m, e mv§[ rece~v_e.~gur _.wr~__e~l___N)_~[.o ~._~,_u~_,r ~se[mS l~rO_r_E~- apply only to me sample testea ana/or inspecteQ, aria are no( iRQicaave o;[rle quarmaes TECHNOLOGIES INC Maxim Tech. e Southwestern Labs 2575 Lone Star Dr. · P.O. Box 224227 Dallas. Texas 75222 Telephone: (214) 831-2700 FAN: (214) ~20-1891 REPORT OF STRUCTURAL STEEL INSPECTION CLIENT: Gulf Bearing, Inc. Attn: Ross Ramsey 501 Industrial Blvd. Grapevine, TX 76051 PROJECT: Gulf Bearing Coppell, Texas CLIENT NO.: 3200037 REPORT NO.: 25569 OATEOFSERVlCE: 9/12/95 AUTHORIZA~ON: Joe White REPORT DATE: 9/18/95 SERVICES: Perform structural steel inspection as detailed below. REPORT OF TESTS Drawings Utilized: Structural Steel Locations/Items Inspeoted: Discrepancies/Comments= Roof level framing between column lines A to H and i to 4. The following items were visually inspected at this time: 2. 3. 4. 5. 6. Anchor bolts, numerous loose nuts and missing flat washers. Joist seat welds are found to be incomplete at girder due to improper weld length. (Detail S3.1/02 and 03) Joist and girder seat welds are found to be incomplete at wall panel angle due to improper weld length. (Detail S3.1/06 and 07) Girder seat to column cap plate welds are not welded at this time, (Erection bolts are installed). (Detail S3.1/01) Joist seat support angle at wall panel embed plate weldments are not properly welded as detailed. (Detail S3.1/07) Initial start of metal decking installation, the erector is performing the screw attachments. We did find numerous screw which did not maintain the full depth penetration at deck to joist support. Time: 7:00 am to 11:00 am Technician: Randy WalckerA ND~.-tevel II %iU3 Report Distribution: MAXIM TECH.~OUTHWESj-ERN LABS (1) Gulf Bearing, irc. (1) Gromatzky, Dupree & Associates (1) Brockette, Davis, Drake (2) Rogers O'8rien (1) City of CoppeLL l~)dsCity Of Coppel,[ Our letters and reports are for the .excys. lve use of_t~e client .to vv~om ~ey .are a.ddressed .a~_d shadl not be _reproduced e .xceflt In. full .wlthqut.the_approva. I o~ the .tes~.n.g m. ooratory.. ~n.e use o! .ou..ma.m.e mgs.~ recav~_..our .wrrnen aal%ro.vql...Puc, lett~.s..ar~ rel~o .ns apply omy ;o me samite ~esteo ano/or mspectee, aha are not m=~caeve