Gulf Bearing-LR 950918 (3)TECHNOLOGIES INC Maxim Tech. e Southwestern Labs 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 REPORT OF IN-PLACE DENSITY CUENT: Gulf Bearing, Inc. Attn: Ross Ramsey 501 Industrial Blvd. Grapevine, TX 76051 PROJECT: Gulf Bearing Coppell, Texas CUENTNO.: 3200037 REPORT NO.: 30507A DATE OFSERVICE: 9/11/95 AUTHORIZA~ON: ongoing REPORT DATE: 9/18/95 SERVICES: Perform in-place density and moisture content tests to determine the degree of field compaction. CONTRACTOR: Rogers O'Brien TEST OF: Bldg.perimeter bkftl # # METHOD OF TEST: DENSITY: ASTM D2922 MOISTURE: ASTM D3017 PROJECT DATA MATERIALS 23525 Dark brown clay 25363 Reddish bwn.clayey sand with some dark brown clay. MOISTURE~ENSITY RELATION~ OPTIMUM MAXIMUM MOISTURE % DENSITY ocr 21.5 99.0 12.5 114.5 SPECIFICATION DENSITY: 952 Dry Density MOISTURE: -12 to +4[ opt. REPORT OF TESTS FIELD OPTIMUM FIELD MAXIMUM TEST MOISTURE MOISTURE DENSITY DENSITY DENSITY NO LOCATION (%) ~) (P~ (P~ (% m~) 1. Buildtn~ line H/15 outside final lift. 22.3 21.5 96.1 99.0 97 2. Building line H/3 outside, final lift. 22.0 21.5 97.6 99.0 99 3. Building line E/1 inside, 1st lift. 11.8 12.5 112.6 114.5 98 4. ~uilding line A/10 outside, 1st lift. 12.2 12.5 114.3 114.5 100 Test results on this report meet project specifications as noted above. Technician: James Gray Started: 09:30AM Stopped: ll:00AM CML Technician Report Distribution: MAXIM TECH.~OUTHW~S_TERN LABS (1) GuLf Bearing, Inc. (1) Gromatzky, Dupree & Associates (1) Brockette, Davis, Drake (2) Rogers O,Brien F. King Cook, P.E. (1) City of CoppeLL ,o p city of co LL Our attars and reports are for the excl.usl, ve u. se ofthe client .to wflom they .ere ad. dressed .an~d shall n~t_.be ~re_Pr,o_clu_c_?d__e~xc.e?~_?_,- full .without the_approva. I of the.testl.n.g ia. ooraz.ory.. ~n.e use o! .ou.ma.m.e rn~js.~ re_ce[_v~.~,_o~r_ apply only to ~rle sample testea arlo/or inspec~eo, arlo are no! irtolca/Jve TECHNOLOGIES INC Maxim Tech. · Southwestern Labs 2575 Lone Star Dr. · P.O. Box 224227 Dallas. Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 REPORT OF IN-PLACE DENSITY CLIENT: Gulf Bearing, Inc. Attn: Ross Ramsey 501 Industrial Blvd. Grapevine, TX 76051 CMENT NO.: 3200037 REPORT NO.: 30709 PROJECT: Gulf Bearing DATE OF SERVICE: 9/15/95 Coppell, Texas AUTHORIZATION: ongoing REPORT DATE: 9/18/95 SERVICES: Perform in-place density and moisture content tests to determine the degree of field compaction. CONTRACTOR: Rogers O'Brien TEST OF: Pour Strip Backfill PROJECT DATA MATERIALS 29953 tannish red clayey sand w/some gravel. MOISTURE/DENSITY RELATIONS OPTIMUM MAXIMUM MOISTURE % DENSITY pcf 9.5 126.0 METHOD OF TEST: DENSITY: ASTM D2922 MOISTURE: ASTM D3017 SPECIFICATION DENSITY: 95% MIN. DENSITY MOISTURE:-1 to + +4% opt. REPORT OF TESTS FIELD OPTIMUM FIELD MAXIMUM TEST MOISTURE MOISTURE DENSITY DENSITY DENSITY NO LOCATION {%) (%) {Pcf) {Pcf} {% max) 1. Pour strip, I'N of 1 line at G.5, 8" below F.F. (retest) 13.0 9.5 119.9 126.0 95 2. Pour strip, i'W of H line at 1.9, 1'0" below F.F. 16.1 * 9.5 115.3 126.0 92 An asterisk (*) appears next to test results which do NOT meet the project specifications as noted above. Technician: Frank Tisdale, CET Started: ll:OOAM Stopped: OI:OOPM Report Distribution: MAXIM TECH. ~THWG&T. ER. SOUTH N LABS (1) Gulf Rearing. i~. ~~ (1) Gr~tzky, D~ree & Associates (1) Brockette, Davis, Orake (2) Rogers O'Bri~ (1) City of Coppe[[ F. King Cook, P.E. 1) City of Coppe[[ 10%7 CME Our I~tterl m~d res)ertl are for the e.xclu~ive u~e of the client to whom they are ed~/eamed arid. shall not be reproduced except in full without the If)provl4 O! the teltll~l Idoo~etory. The Ule of oumarne rnu~t rec4ave our written Grovel. Our lettem ~nd rel)ortl ~opty only to the sample tested attcl/cx inspected, and ore not indicative of the quantitiee of al)patently idenficel or similor products.