Loading...
Gulf Bearing-LR 950830TECHNOLOGIES INC · Maxim Tech.. Southwestern Labs 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 CUENT: PROJECT: SERVICES: REPORT OF CONCRETE COMPRESSIVE STRENGTH Gulf Bearing, Inc. Attn: Ross Ramsay 501 Industrial Blvd. Grapevine, TX 76051 CLIENT NO.: 3200037 REPORT NO.: 29408 Gulf Bearing DATE OF SERVICE: 8/21/95 Coppell, Texas AUTHORIZATION: ongoing REPORT DATE: 8/30/95 Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. CONTRACTOR: Rogers O' Brian CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 4000psi @ 28 DAYS SLUMP: 5" Max. AIR: N/A METHOD OF TEST: ASTM C-39 ASTM C- 143 PROJECT DATA CLASS OF CONCRETE: Mix Number 44 DATE OF PLACEMENT: 8/21/95 TIME SAMPLED: 07:45AM BY: Larry Bracken TEMPERATURE ('F)-AIR: 79 CONCRETE: 87 TRUCK NO: 300 TICKET NO: 7013199 AIR CONTENT(%): 4.5 LOCATION OF PLACEMENT: Panel ~,~22 mlddle CYLINDER MEASURED MARKED SLUMP DATE AGE SET NO. (inches) TESTED (days) 1 1 5.50 8/24/95 3 1 2 5.50 8/24/95 3 1 3 5.50 8/28/95 7 1 4 9/18/95 28 1 5 9/18/95 28 1 6 HOLD HOLD REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE DIAMETER AREA LOAD STRENGTH (in,) (sq.in.) (lbs. force) (psi) 6.00 28.27 100360 3550 6.00 28.27 107200 3790 6.00 28.27 107710 3810 REMARKS Report Of Tests Continued On Page 2 1001 LW Our letters and reports are for the exc usive use of the c ant to whom they are addressed and shall not be reproduced except in full without the approval of the testing aboratory The use of ourname must race ve our written approval. Our letters and reports apply only to the sample tested and/or inspected, and are not nd cat ve of the quantities of apparently identical or similar products· Gulf Bearing, Inc. CLIENT NO. 3200037 DATE OF SERVICE: 8/21/95 REPORT NO. PAGE 2 SET NO. 1 29408 REPORT OF TESTS (Continued) ADDITIONAL COMMENTS Added 10 gallons water prior to test sample. discharge. Test sample taken at truck Technician: Larry Bracken Started: 06:30AM Stopped: ll:30AM Report Of Tests Continued On Page 3 1001 LW Our letters and reports are for the exclusive use of the c ient to whom they are acidressed and shall not be reproduced except in full without the approval of the testing aboratory The use of ourname must receive our written approval. Our letters and reports apply only to the sarnple tested and/or inspected, and are not nd cat ye of the quantities of apparently identical or similar products, Gulf Bearing, Inc. CLIENT NO. 3200037 DATE OF SERVICE: 8/21/95 REPORT NO. PAGE 3 SET NO. 2 29408 CONTRACTOR: Rogers O'Brien CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 4000psi @ 28 DAYS SLUMP: 5" Max. AIR: N/A METHOD OF TEST: ASTM ¢- 39 ASTM C- 143 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Cont i nued) PROJECT DATA CLASS OF CONCRETE: Mix Number 44 DATE OF PLACEMENT: 8/21/95 TIME SAMPtED: iO:07AM BY: Larry Bracken TEMPERATURE ('F) - AIR: 84 CONCRETE: 89 TRUCK NO: 573 TICKET NO: 7013210 AIR CONTENT(%): 5.0 LOCATION OF PLACEMENT: Panel ~/82 bottom CYLINDER MEASURED MARKED SLUMP DATE SET NO. (inches) TESTED REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH -6 X 12 CYLINDERS MAXIMUM AGE DIAMETER AREA LOAD (days) (in.) (sq.in.) (lbs. force) 2 1 6.25 8/24/95 3 2 2 6.25 8/24/95 3 2 3 6.25 8/28/95 7 2 4 9/18/95 28 2 5 9/18/95 28 2 6 HOLD HOLD COMPRESSIVE STRENGTH (psi) 6.00 28.27 85350 3020 6.00 28.27 88960 3150 6.00 28.27 89600 3170 REMARKS ADDITIONAL COMMENTS: Test sample taken at truck discharge. Technician: Larry Bracken Started: 06:30AM Stopped' ll:30AM Report Distribution: MAXIM TECH.~SOUTHWESTERN LABS (1) (;u[f Bearing, Inc. (1) Gromatzky, Dupree & Associates ~ (1) Brockette, Davis, Drake ,\, (2) Rogers o'arien F. King Cook, P.E (1) City of Coppe[[ ' ,O~)l)LwCity of Coppe[[ Our letters and reports are for the exc us ve use of the client to wi3om they are addressed ancl shall not be reproduced except in fu without the approva of the testng aboratory. The use of ourname must receive our written approval. Our letters and reports apply only to the sample tested and/or inspected, and are not ind cat ve of the quant t e5 of apparent y identical or similar products.