Gulf Bearing-LR 950809TECHNOLOGIES INC
Maxim Tech. e Southwestern Labs
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telephone: (214) 631-2700
FAX: (214) 920-1891
REPORT OF
REINFORCING STEEL INSPECTION
CUENT:
Gulf Bearing, Inc.
Attn: Ross Ramsey
501 Industrial Blvd.
Grapevine, TX 76051
PROJECT: Gulf Bearing
Coppell, Texas
CLIENT NO.: 3200037
REPORT NO.: 28572
DATE OF SERVICE: 8/05/95
AUTHORIZA~ON: ONGOING
REPORT DATE: 8/09/95
SERVICES: Reinforcing steel inspection:
REPORT OF TESTS
On this date, reinforcing steel was observed for proper size, placement and
alignment prior to concrete placement. The results of this inspection are
attached and were furnished to the contractOr at the time of inspection.
Technician time: 8:30am-10:30am
ll:30am- l:00pm
Technician: Yefim Palchik, MSCE
Senior Consultant
Report Distribution: MAXIM TECH.e~OUTH~N LABS
(1) GuLf Bearing, Inc.
(1) Gromatzky, Dupree & Associates
(1) Brockette, 0avis, 0rake
(2) Rogers O'BrJen F. King Cook, P.E.
(1) city of Coppel.[
(1) City of Coppet.[
1099 LW
Our letters and rel3orts are for the exctusive use of the c lent to wflom they are addressed and shall not be reproduced excelot in
ful without the approval of the testing aiooratory. The use o.f ~u.r. na.m.e m.u~.t receive...our wt. itten app.,ro~c~l._.,(~, lette?s.,and re~o~s
apply only to the sample tested and/or inspectecl, aha are no( tnolcatlve o1' tile (3uantltleS O't apparem y aero ca or s m ar proaucts.
... OUTH~,/ESTERN LAE~NIRATORIES
Materials, environmental and geotechnical engineering, nondestructive, metallurgical and analytic-I services
2575 Lone Star Drive · P.O. Box 22&227, Dattas, Texas 75222 · 214/631-2700
REPORT OF
REINFORCING STEEL INSPECTION
CLIENT:
PROJECT:
Client No.: JZ-o
Report No.:
Date of Service
Page / of
SERVICE: Perform reinforcing steel inspection as detailed below.
INSPECTION RESULTS
Location and Items Inspected: '~/,"/_~_ e 7,
/
/
-i .// / / /
IT.S INSPE~ED: CORRE~ INCORRE~ ITEMS INSPE~£D: ] CORRE~ INCORRE~ IT.S INSPE~ED: ~RRE~ INCORRE~
Placing Drawings ~r Lengtht Col~n Ties Properly
Approved ~F and Shape ~w/ Tied and. ~ced ~'~
Bar Size %,/ Proper ~r Plac.ent I ~/' StirNp $~cing/~pe ~.
Bar Grade ~ Properly Tied ~ Welded Splices
Rehar Clean ~ ~wel Bars in Place I ~' Mechanical Splices ~/--
Fo~ Clean ~ Proper Bar Supports ~ Proper C~er ~
No. of Bars ~ Lapped Splices /
/ /
132
SOUTHW. EST~RN LABO~ATORI ES/
EM, u
~e~or' s Signature
INC ·
TECHNOLOGIES INC
Maxim Tach. · Southwestern Labs
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telephone: (214) 631-2700
FAX: (214) 920-1891
REPORT OF
REINFORCING STEEL INSPECTION
CUENT:
Gulf Bearing, Inc.
Attn: Ross Ramsey
501 Industrial Blvd.
Grapevine, TX 76051
PROJECT: Gulf Bearing
Coppell, Texas
CLIENT NO.: 3200037
REPORT NO.: 28349
DATE OF SERVICE: 7/28/95
AUTHORIZATION: JOE
REPORT DATE: 8/08/95
SERVICES: Reinforcing steel inspection:
REPORT OF TESTS
On this date, reinforcing steel was observed for proper size, placement and
alignment prior to concrete placement. The results of this inspection are
attached and were furnished to the contractor at the time of inspection.
technician time: 9:30am-ll:3Oam
Technician: Yefim Palchik, MSCE
Senior Consultant
Report Distribution: MAXIM TECH.,SOUTHWES~RN
(1) GuLf Bearing, Inc.
(1) Gromstzky, Dupree & Associates
(1) Brockette, Davis, Drake
(2) Rogers O'Brien F. King Cook, P.E.
(1) City of CoppeLt
lO~J)twCity of CoppeLL
Our letters and rel::)orts are for tlqe exclusive use of the client to w~om they are acldressecl and slqall not be _reproduced except in
fiji witl~out the approval of tine testinc3 )at)oratory The use of ourname must recmve our w~ tten apDroval, uur letters anti reports
apply only to tl~e sample testecl and/or insoectei~, anti are not ind cat ye of the quantities of apparently ide~lcal or similar Droducts.
LABS
C_IUTHUqlESTERN LABt ClATORIES
Materials, environmental and geotechnical engineering, nondestructive, metallurgical and analytical services
257~ tone Star Dr~ve · P.O. Box 22t~227, Dallas, Texas 7~222 · 21&/6:~1-2700
REPORT OF
REINFORCING STEEL INSPECTION
CLIENT:
PROJECT:
Client No.: 3
Report No.:
Date of Service:
Page [ of
SERVICE: Perform reinforcing steel inspection as detailed below.
INSPECTION RESULTS
Location and Items Inspected: 7~'/~ -~ ~ ~/~ ~/~ ' P~--7 ~, /~D~<iT/~-D
ITEMS INSPECTED: CORRECT INCORRECT ITEMS INSPECTED: CORRECT INCORRECT ITEMS INSPECTED: CORRECT INCORRECT
Placing Drawings Bar Length Column Ties Properly
Approved ~W' and Shape %/ Tied and Spaced
Bar Size ~/ Proper Bar Placemen~ ~/ Stirrup SPacing/Type ~ .'~
Bar Grade ~, Properly Tied ~ Welded Splices
Rebar Clean ~ Dowel Bars in Place ~/ Mechanical Splices ~&~.~-
Form Clean %w, Proper Bar Supports ~/ Proper Cover
No. of Bars ~.- Lapped Splices
/ /
132
SOUTHWEST]~RN LABORATORIES, INC.
I ~z~e~or ' s Slgnature
TECHNOLOGIES INC
Maxim Tech.· Southwestern labs
2575 Lone Star Dr. · P.O. Box 224227
Dallas. Texas 75222
Telephone: (214) 631-2700
FAX: (214) 920-1891
REPORT OF
REINFORCING STEEL INSPECTION
CUENT:
Gulf Bearing, Inc.
Attn: Ross Ramsay
501 Industrial Blvd.
Grapevine, TX 76051
PROJECT: Gulf Bearing
Coppell, Texas
CLIENT NO.: 3200037
REPORT NO.: 28348
DATE OF SERVICE: 7/27/95
AUTHORIZA%]ON: JOE
REPORT DATE: 8/08/95
SERVICES: Reinforcing steel inspection:
REPORT OF TESTS
On this date, reinforcing steel was observed for proper size, placement and
alignment prior to concrete placement. The results of this inspection are
attached and were furnished to the contractor at the time of inspection.
Technician time: 4:00pm-6:00pm
Technician: Yefim Palchik, MSCE
Senior Consultant
Report Distribution: MAXIM TECH.,SOUTHWES3i~R~N LABS
(1) Gutf 8earing, Inc.
(1) Gr~etatzky, Dupree & Associates
(1) lirockette, Davis, Drake .
(2) Rogers O'Srie~ F. King C°o~, P.E.
(1) City of Coppett
(1) City of Coppe[I.
1099 LW
Our attars and re0orts are for tt~e exclusive use of the clierfl: .to w~om they are addressed and shall not ~e_reor. oduced exceOt in
apoly only to the sample tested and/or ~nsoecteo, and are ,,u..,,u.~.,.~ ~ u,~ ~ua.,.,.,~ ~ ~. · ~ -
-- UTHUVESTERN LAi RATORIES
Materials, environmental and geotechnical engineering, nondestructive, metallurgical and analytical services
2575 Lone Star Drive · P.O. Box 224227, Oat tas, Texas 75222 · 214/631-2700
REPORT OF
REINFORCING STEEL INSPECTION
CLIENT:
Client No.: _]Eo oo37
Report No.: ~3~ .~
Date of Service: 7--~(-~-=
Page / of [
SERVICE: Perform reinforcing steel inspection as detailed below.
INSPECTION RESULTS
Location and Items Inspected:
IT~4S INSPECTED: CORRECT INCORRECT ITEMS INSPECTED: CORRECT INCORRECT ITEMS INSPEur=m: CORRECT INCORRECt'
Placing Drawings Bar Length Column Ties Properly
Approved t~/ an~ Shape ~W' Tied and Spaced
Bar Size ,../* Proper Bar Placemen~ ~,/ Stirrup Spacing/Type
Bar Grade ~,. Properly Tied ~.. Welded Splices
Rebar Clesn ~/ Oowel Bars in Place ~.' Mechanical Splices
Form Clean ~,' Proper Bar Supports ~' Proper Cover %,/
No. of Bars w/ Lapped Splices ~"
Discrepancies/Comments:
132
SOUTH,. ES~RN LABORATORIES,
, ~ 'S Signature
INC ·
TECHNOLOGIES INC
Maxim Tech.* Southwestern Labs
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telephone: (214) 631-2700
FAX: (214) 920-1891
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
CUENT:
Gulf Bearing, Inc.
Attn: Ross Ramsey
501 Industrial Blvd.
Grapevine, TX 76051 CUENT NO.: 3200037
REPORT NO.: 28370
PROJECT: Gulf Bearing DATE OF SERVICE: 7/28/95
Coppell, Texas AUTHOR;ZA~ION: Joe
REPORT DATE: 8/07/95
SERVICES:
Sample concrete at location of placement, perform required field tests,
prepare and test concrete compressive strength specimens.
CONTRACTOR: Rogers O'Brien
CONCRETE SUPPLIER: Lattimore
PLANT: 7
SPECIFICATION REQUIREMENTS
STRENGTH: 4000psi @ 28 DAYS
SLUMP: 3 - 5"
AIR: 3 - 6 %
METHOD OF TEST: ASTM C-39
ASTM C- 143
PROJECT DATA
CLASS OF CONCRETE: Mix Number 40
DATE OF PLACEMENT: 7/28/95
~ME SAMPLED: 10 :OOAM BY: Frank Tisdale,
TEMPERATURE ('F)- AIR: 93 CONCRETE: 89
TRUCK NO: 570 . .~CKET NO: 7012479
AIR CONTENT(%): 3.0
LOCATION OF PLACEMENT:
Tilt up panel ~/62.
CET
CYLINDER MEASURED
MARKED SLUMP DATE AGE
SET NO. (inches) TESTED (days)
1 1 5.00 8/04/95 7
1 2 8/25/95 28
1 3 8/25/95 28
1 4 HOLD HOLD
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
MAXIMUM COMPRESSIVE
DJLAMETER AREA LOAD STRENGTH
(in.) (sq.in.) (lbs. force) (psi)
6.00 28.27 98400 3480
REMARKS
ADDITIONAL COMMENTS:
No water added, sample taken at pump discharge.
Technician: Frank Tisdale, CET Started: 09: 30AM Stopped: 12:30PM
Report Of Tests Continued On Page 2
1001 LW
Our letters and reports are for the exclusive use of the client to whom they are aqldressed and shall not be reproduced excel3t in
fu without the approval of the testing aOoratory: The use o~' ~3u[na.rn, · m.u%t rece[ve..pur wt. itten app.,ro¥~al._..._Ou_,r
apply only to the sample tested and/or nspecte(3, ano are not inoicauve
Gulf Bearing, Inc.
CLIENT NO. 3200037
DATE OF SERVICE: 7/28/95
REPORT NO.
PAGE 2
SET NO. 2
28370
CONTRACTOR: Rogers O' Brien
CONCRETE SUPPLIER: Lattimore
PLANT: 7
SPECIFICATION REQUIREMENTS
STRENGTH: 4000psi @ 28 DAYS
SLUMP: 3 - 5"
AIR: 3-6%
METHOD OF TEST: ASTM C-39
ASTM C-143
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
(Continued)
PROJECT DATA
CLASS OF CONCRETE: Mix Nuaber 40
DATE OF PLACEMENT: 7/28/95
TIME SAMPLED: 11: 15AM BY: Frank Tisdale,
: TEMPERATURE ('F) - A~R: 97 CONCRETE: 93
TRUCK NO: 332 TICKET NO: 7012492
AIR CONTENT(%): 2.0
LOCATION OF PLACEMENT:
Tilt panel #57
CET
CYLINDER MEASURED
MARKED SLUMP DATE
SET NO, (inches) TESTED
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
MAXIMUM
AGE DIAMETER AREA LOAD
(days) (in.) (sq.in.) (lbs. force)
2 1 4.50 8/04/95 7
2 2 8/25/95 28
2 3 8/25/95 28
2 4 HOLD HOLD
COMPRESSIVE
STRENGTH
(ps~
6.00 28.27 88760 3140
REMARKS
ADDmONAL COMMENTS:
10 gallons of water added prior Co sampling. Sample taken at pump
discharge. Contractor notified of air content & concrete temperature.
Technician: Frank Tisdale, CET Started: 09:30AM Stopped: 12:30PM
Report Distribution: MAXIM ~T~
TECH.eSOUTHWE~ RN LABS
(1) Gulf Bearing, Inc.
(1) Gromatzky, Dupree & Associates
(1) Ilrockette, Davis, Drake
(2) Rogers O,lirien F. King Cook, P.E.
(1) City of Coppe[[
IO~)LwCity of Coppe[[
Our etters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced excel3t in
full witttout the approval of the testing IqDoratory,. The use o~f pu[,na.m,.e mys. t~ rece~ve~..,our _w;itte_n_.ap_%r.?¥~aL._.,.O~j I..e. tte~fs_.a~n.~fe,.?,,o,~s.
ap!oly only to the sample tested and/or mspectea, and are noz JlqQICatlVe PT [ne cluan[mes pT apl3u[e,,uy ,u=,,,,~, ,~. 0,,,,.o...ruud,=.