First United-LR 990329i G · GEOTECHNIC&L ENGINEERING E GEE Consultants, Inc. E ° CONSTRUCTION MATERIALS TESTING , ~.~.:9 · !.214) 352-5433 · Fax (214'~ 352-6972 10046 Monroe Drive ° Dallas, Texas -"-'~'~ REPORTOF CONCRETE MIX INSPECTION Reoort Date: March 29. 1999 Date Concrete Placed: March 1. 1999 ';ta::c,,:c Che,t. First United Methodist Church of Coppell Area 2:5.2-? Square inciaes Pro..;ect: First United Methodist Church-Sanctumw C,mcr~te Report No. 24 Coppell. Texas Conrractm': Strand Tech. Inc. Proje~[ No.: 298-0394 Co.crete Supp.er and Plant: Mid-Cities Ready Mix L.;cantm of Plac¢:nent: Ramp MATERIALS ......... s,, ...... ~,.., INSPECTION DATA Cemem: '?rote Sampled: ~2:00 pm F~,. ~sh Sample Locatmn: o0' S.6c 6' W.,.ff 5.E ~crner ~t' bm:drag Truck;Ticket N 762.-52807 Coarse .-kgg regale. 'Fcnlper:iture: h~tern:ed~ate &ggreg::te: .-Mill',refit Range: 7ti-F F!ne A,;g..'rgate: ('.mcrct~ Rang-~: '42- F . \Veamer C,H1GI[IOIIS.: 'rime Starteo: I'. '50 .,m T:me Completed: ...i :50 pm Addec Water: :'~ Gallom, Sample Air C.mte::t: :'::- .: N. A Total C::Nc '¥':u-o3 Placed: Rcqmred Strengta - Lbs. :.ti- FL:MC i01 7 03..08..'99 86.380 3.060 FUMC [02 28 ,33..'29.'99 112.600 3.980 FUMC i03 28 03."29;99 118. 100 4. 180 FUMC 104 H HOLD ~'r,~: t'-3:.('-~9.('..-;3 :t..less 5.ote~e~""~rOmer'z.-se, Cx lilldel'S Mat.lc By: HO Remarks ,uld.'or Uls[rlbu[lOll: cc: Ms. Lynn Johnson - First United Methodist Church Mr Char:,es Harper - Harper Perkins Architects Mr. Lam,' Davis - City of Coppetl Mr. Bill Anderson - Dowdey. Anderson & Associates. Inc. Mr. Mel Fencl - Offutt Construction