Loading...
Gunner P2-LR010104~ GEO"'-"~HNICAL, ENVIRONMENTAL AND MATERIALS E~'"'~NEERS DA, ,S FORT WORTH HOUSTON AUSTIN LC. VIEW 1 ~050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080 Concrete Compression Test Report Client: Archon Group Report Distribution: (1) Archon Group (1) North American Communities Project: Karrington Apartments (1) O.D. Construction Consulting (1) City of Coppell (1) City of Coppell TMI Report No.: DC00-040-107 (1) Archon Group Report Date: 01/04/2001 Specifications Test Data Strength 3000 psi @ 28 Days Placement Date 12/11/2000 Slump 4 in min 6 in max Sampled By Randolph Shaheed Air Content 3 % min 6 % max Weather Clear / Cold Concrete Temperature 55° F min 95° F max Supplier/Mix TXI/8272 Ambient Temperature n/a Air Content Method Ticket Number: 2794284 Time Batched: 10:05 AM Time Sampled: 11:30 AM Slump: 5 in Air Content: 3.7 % Unit Weight: Concrete Temperature: 55° F Ambient Temperature: 34° F Yardage (c.y.): Placement Location: Paving at Building 1 Sample Location: 50' South from SW corner of building Age, Max Load Area Strength Fracture Set # Cyl~der Test Date (days) Obs. force) (sq.in.) (psi) Type I KARl2110001 12/18/2000 7 64480 28.27 2280 unbonded cap 1 KARl2110002 01/08/2001 28 I KARl2110003 01/08/2001 28 1 KARl2110004 Hold Normal cylinder size: 6" x 12" Test Method(s): ASTM C-172, ASTM C-31, ASTM C-143, ASTM C-231, ASTM C-1064, ASTM C-138, ASTM C-39 The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. -, ~.-l~age i of ! OISSD '~