First United-CS 990403Calculations for Drainage Plan: / GIVEN: Approx. 5.0 acres are being developed (some development currently exists). Tl~area of concern covers about 3.0 acres. Thc pre-development area has a current flow of 11.70 cfs into thc alley. The proposed design would put 14.39 cfs into the alicy. *Calculations d~termined using Hydro-S5 Int~ns#les DETERMINE: Required detention area to ke~p the flow into ti~ alley at ll.70cf,. SOLUTION: Using tho Modified Rational Mcthod .Ik'temion l~in Dezign Example in thc City of Dallas Drainage Design Manual. The area of concern is divided into 2 sections. Present conditions Q = CIA sec I c = 0.35 Itoo = 7.6 in/hr Iloo = 7.6 in/hr A = 1.22 acres A = 1.71 acrca Qloo = 3.25 cfs Q~oo = 8.45 cfa Total Qloo = 11.70 cfa Fut~ conditions Q = CIA Sec I C = - 0.50 Sec2 C = 0.75 Tc = 15 min. Tc = 15 min. Iloo = 7.6 in/hr I~oo == 7.6 in/hr A = 1.22 acres A = 1.71 act, Q~oo = 4.64 cfs Q~oo = 9.75 cf, Total Q~oo = 14.39 cfs Check various duration storms 15 min. I = 7.6 Q~ = 0.5 x 7.6 x 1.22 = '4.64 cf, ' Qa = 0.75 x 7.6 x 1.71 = 9.75 cfs QT = 14.39 cfa 20 min. I = 7.0 Q~ = 0.5 x 7.0 x 1.22 = 4.27 cf~ Qa = 0.75 x 7.0 x 1.71 = 8.98 cfa QT = 13.25 cfs 30 min. I = 5.8 Q~ = 0.5 x 5.8 x 1.22 = 3.54cfs Qa = 0.75 x 5.8 x 1.71 = 7.44 cfa QT = 10.98 cfs 40 min. I = 5.0 Qz = 0.5 x $.0 x 1.22 = 3.05 cfs Q2 = 0.75 x 5.0 x 1.71 = 6.41cfs QT -- 9.46 cfs 50 min. I -- 4.4 Q~ -- 0.5 x 4.4 x 1.22 -- 2.68 cfs Q2 -- 0.75 x 4.4 x 1.71 -- 5.64 cfs Q~r -- 8.32 cfs 60 min. I = 4.0 Q1 = 0.5 x 4.0 x 1.22 -- 2.44cfs Q2 -- 0.75 x 4.0 x 1.71 = 5.13 cfs QT -- 7.57 cfs 70 min. I -- 3.7 Q~ -- 0.5 x 3.7 x 1.22 -- 2.26cfs Q2 = 0.75 x 3.7 x 1.71 = 4.75 els Q~r = 7.01 cfs 80 min. I -- 3.4 Q~ -- 0.5 x 3.4 x 1.22 -- 2.07cfs Q~ = 0.75 x 3.4 x 1.71 = 4.36 cfs QT = 6.43 cfs Maximum Storage Volume is determined by deducting the volume of runoff released during the time of inflow from the total inflow for each duration. Inflow -- Storm duration X respective peak discharge X 60 sec/min Outflow -- Half of the respective inflow duration X control release discharge X 60 sec/min 15 min. Storm Inflow 15 x 14.39 x 60 sec/min = 12,951 cf Outflow 0.5 x 30 x 11.70 x 60 sec/min = 10~530 cf Storage = 2,421 cf 20 min. Storm Inflow 20 x 13.25 x 60 sec/min = 15,900 cf Outflow 0.5 x 35 x 11.70 x 60 sec/min = 12,285 cf Storage = 3,615 cf 30 min. Storm Inflow 30 x 10.98 x 60 sec/mn = 19,764 cf Outflow 0.5 x 45 x 11.70 x 60 sec/min = 15,795 cf Storage = 3,969 cf 40 min. Storm Inflow 40 x 9.46 x 60 sec/min = 22,704 cf Outflow 0.5 x 55 x 11.70 x 60 sec/min = 19,305 cf Storage = 3,399 cf Maximum volume required is 3,969 cf at the 30 min. Storm duration.