Gulf Bearing-LR 950713TECHNOLOGIES INC · Maxim Tech. ·Southwestem Lab. 2575 Lone Star Dr. · P.O. Box 22422.7 Dallas, Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 REPORT OF CONCRETE COMPRESSIVE STRENGTH CLIENT: Gulf Bearing, Inc. Attn: Ross Ramsey 501 Industrial Blvd. Grapevine, TX 76051 PROJECT: Gulf Bearing Coppell, Texas CLIENT NO.: 3200037 REPORT NO.: 26286 DATE OF SERVICE: 6/15/95 AUTHORIZATION: Joe REPORT DATE: 7/13/95 SERVICES: Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. CONTRACTOR: Rogers O'Brien CONCRETE SUPPLIER: Lattimore PLANT:' 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 2-4" AIR: 5 +- 1% METHOD OF TEST: ASTM C-39 ASTM C- 143 PROJECT DATA CLASS OF CONCRETE: Mix Number 38 DATE OF PLACEMENT: 6/15/95 TIME SAMPLED: 06:45AM BY: Frank Tisdale, CET TEMPERATURE ('F)-AIR: 69 CONCRETE: 81 TRUCK NO: 572 TICKET NO: 7010768 AIR CONTENT(%): 4.0 LOCA~ON OF PLACEMENT: East half. of east paving area, 70 feet south and 104 feet east of southeast building corner. REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MEASURED MAXIMUM COMPRESSIVE MAR KED SLUM P DATE AGE LOAD STRENGTH SET NO. (inches) TESTED (days) (lbs. force) (ps~ 1 1 5.50 6/22/95 7 91820 3250 1 2 5.50 7/13/95 28 120600 4260 1 3 5.50 7/13/95 28 118510 4190 1 4 HOLD HOLD REMARKS ADDITIONAL COMMENTS: 15 gallons of water was added prior to sampling. Technician: Frank Tisdale, CET Started: 06:00AM Stopped: 05:30PM Report Of Tests Continued On Page 2 1001 LW Our letters and reports are for the exclusive use of the cent to whom they are addressed and shall not be reproduced except in full withqut the approva of the test ng laboratory; Th.e use o.f .ou.r. na.m. e m,us..t receive...gur ,written al3~.roya. I. _.Ou.r letters, and rep. o~s apply only to the sample tested and/or inspecteD, and are not indicative oT the quan[t es ol al0parem y ~oen[~cal or sim,ar proouc~s. Gulf Bearing, Inc. CLIENT NO. 3200037 DATE OFSERVICE: 6/15/95 REPORT NO. PAGE 2 SET NO. 2 26286 CONTRACTOR: Rogers O'Srien CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 2-4" AIR: 5 +- 1% METHOD OF TEST: ASTM C-39 ASTM C- 143 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) PROJECT DATA CLASS OF CONCRETE: Mix Number 38 DATE OF PLACEMENT: 6/15/95 ~ME SAMPLED: 08:31AM BY: Frank Tisdale, CET TEMPERATURE ('F)-AIR: 75 CONCRETE: 81 TRUCK NO: 280 ~CKET NO: 7010777 AIR CONTENT(%): 4.5 LOCA3qON OF PLACEMENT: East half of east paving area, 35 feet north and 127 feet east of southeast building corner. CYLINDER MARKED SET NO. MEASURED SLUMP (inches) REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE DATE AGE LOAD STRENGTH TESTED (days) (lbs. force) (ps0 2 1 5.50 6/22/95 7 91220 3230 2 2 5.50 7/13/95 28 115950 4100 2 3 5.50 7/13/95 28 120080 4250 2 4 HOLD HOLD REMARKS Technician: Frank Tisdale, CET Started: 06:00AM Stopped: 05:30PM Report Of Tests Continued On Page 3 1001 LW Our letters and reports are for the exclusive use of the client .to whom they are a(;Idressed .a~.~d shall not .be _repr.o.duced e)~cept In. fu without the aDI3roval of the testing laboratory. The use oT 9u.r. na.m,e mgs.t recetve...our wr. ~en al3P..ro.v~.l._.uu.r ~et~efs.,ano re~s al~ply only to the sample tested and/or insl~ecterd, and are not indicative or tne ~3ua131:l~les or apl~arem3y luet~lCal or s~m.ar proouc[s. Gulf Bearing, Inc. CLIENT NO. 3200037 DATE OF SER~CE: 6/15/95 REPORT NO. PAGE 3 SET NO. 3 26286 CONTRACTOR: Rogers O'Brien CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 2-4" AIR: 5 +- 1% METHOD OF TEST: ASTM C-39 ASTM C- 143 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Cent lnued) PROJECT DATA CLASS OF CONCRETE: Mix Number 38 DATE OF PLACEMENT: 6/15/95 ~ME SAMPLED: 10:43AM BY: Frank Tisdale, CET TEMPERATURE ('F) - AIR: 81 CONCRETE: 81 TRUCK NO: 574 TICKET NO: 7010803 AIR CONTENT(%): 6.0 LOCATION OF PLACEMENT: East half of east paving area, 140 feet north and 128 feet east of southeast bldg. corner. CYLINDER MARKED SET NO. MEASURED SLUMP (inches) REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 8 X 12 CYLINDERS MAXIMUM COMPRESSIVE DATE AGE LOAD STRENGTH TESTED (days) (lbs. force) (osi) 3 1 5.25 6/22/95 7 91820 3250 3 2 5.25 7/13/95 28 113850 4030 3 3 5.25 7/13/95 28 114210 4040 3 4 HOLD HOLD REMARKS Technician: Frank Tisdale, CET Started: 06:00AM Stopped: 05:30PM Report Of Tests Continued On Page 4 1001 LW Our letters and reports are for the exclusive use of the client to whom they are addressed and shall not be_reproduced ex. cept in. full without the approval of the testing al3oratory The use of ourname m.us.t rece~ve..gur ~:r. itten appro.va..I...ou.r lette.rs..an(3 re~0~s apply only to the sample tested and/or insl3ecte~l, and are not nd cat ve oT the quantities ol apparer~ly iaen~cai or s~m~ar proouc~s. Gulf Bearing, Inc. CLIENT NO. 3200037 DATE OF SERVICE: 6/15/95 REPORT NO. PAGE 4 SET NO. 4 26286 CONTRACTOR: Rogers O'Brien CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 2-4" AIR: 5 +- 1% METHOD OF TEST: ASTM C- 39 ASTM C- 143 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Cent i nued) PROJECT DATA CRASS OF CONCRETE: Mix Number 38 DATE OF PLACEMENT: 6/15/95 TIME SAMPLED: 12: 35PM BY: Frank Tisdale, CET TEMPERATURE ('F) - AIR: 87 CONCRETE: 87 TRUCK NO: 572 TICKET NO: 7010810 AIR CONTENT(%): 2.5 LOCATION OF PLACEMENT: East half of east paving area, 225 feet north and 97 feet east of southeast building corner. CYLINDER MARKED SET NO. MEASURED SLUMP (inches) REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - § X 12 CYLINDERS MAXIMUM COMPRESSIVE DATE AGE LOAD STRENGTH TESTED (days) (lbs. force) (ps~] 4 1 5.50 6/22/95 7 91940 3250 4 2 5.50 7/13/95 28 120070 4250 4 3 5.50 7/13/95 28 122680 4340 4 4 HOLD HOLD R E MAR KS ADDITIONAL COMMENTS: All test results comply with the project specifications as noted except as marked (*). 20 gallons of water was added to truck prior to sampling. Contractor notified of low air content. Also, contractor notified of slump. Technician: Frank Tisdale, CET Started: 06:00AM Stopped: 05:30PM Report Of Tests Continued On Page 5 1001 LW Our letters and reports are for the exclus ve use ofthe cent .to w~om they are addressed atnd shall not .be _repro.d. uced ex, cept In. full without the approva of the testing aboratory ~ne use OT our. name m.us.t receive.,..our wTr~en app.roya, t_.uu,r Ieee,rs aha re~o~s_ apply only to the sample tested and/or inspectei:l, and are not inolcative or the quan~mes or apparently ioenaca~ or s~m,ar proouc[s. Gulf Bearing, Inc. CLIENT NO. 3200037 DATE OFSERVlCE: 6/15/95 REPORT NO. PAGE 5 SET NO. 5 26286 CONTRACTOR: Rogers O'Brien CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 2-4" AIR: 5 +- 1% METHOD OF TEST: ASTM C-39 ASTM C- 143 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) PROJECT DATA CLASS OF CONCRETE: Mix Number 38 DATE OF PLACEMENT: 6/15/95 TIME SAMPLED: 03: 37PM BY: Frank Tisdale, CET TEMPERATURE ('F) - AIR: 90 CONCRETE: 88 TRUCK NO: 464 33CKET NO: 7010835 AIR CONTENT(%): 4.5 LOCATION OF PLACEMENT: East half of east paving area, 220 feet south and 133 feet east of northeast building corner. CYLINDER MARKED SET NO. MEASURED SLUMP (inches) REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE DATE AGE LOAD STRENGTH TESTED (davs]l (lbs. force) (ps~ 5 1 5.00 6/22/95 7 83580 2960 5 2 5.00 7/13/95 28 110420 3900 5 3 5.00 7/13/95 28 110400 3900 5 4 HOLD HOLD REMARKS ADDmONAL COMMENTS: Note: There was an one hour and 10 minute delay between l:20pm and 2:30pm due to no trucks onsite. No water was added to truck. Technician: Frank Tisdale, CET Started: 06:00AM Stopped: 05:30PM Report Distribution: MAXIM TE~S (1) GuLf Bearing, Inc. (1) Gro~atzky, D~ree & Associates (1) Brockette, Davis, Drake (2) Rogers O'Brien (1) City of Coppel. L ' (1) City of Coppe[[ 1001 LW Our letters and reports are for the exc usive use of the cient to whom they are addressed and shall not .be reproduced except in full without the approval of the testing aboratory The use of ourname must receive our wt. itten approv, a.L Ou.r letters and reRo~s apply only to the sample tested and/or inspecte~:l, and are not indicative of the Quantities OT apparently ioenttca~ or similar proouc~s.