First United-CS 980721 Coppell. Texas 75019
/,/'----~/~ The City With A Beautiful Future 972-462-0022
k__// //_._~ ~,0 aox478
July 21, 1998
Mr. William Anderson
Dowdey, Anderson & Associates, Inc.
5225 Village Creek Dr., Suite 200
Piano, TX 75093
RE: First United Methodist Church
Dear Mr. Anderson:
The City of Coppell has received and reviewed the referenced plans and has the following comments to
offer:
1. Indicate which paving/structures are proposed and which are existing. Show drive widths and
radii for all paving.
2. All paving requires 6" lime-stabilized subgrade as per the City of Coppell Subdivision
Ordinance. Any variance request should be sent via letter to the City Engineer. A variance of
either increased thickness or strength has been allowed in the past. All paving within City right-
of-way will require subgrade stabilization.
3. On the water and sanitary sewer plan, show the size and location of all water and sanitary sewer
services (existing and proposed). Also indicate the proposed grade for the sewer services.
4. Will the new building require new domestic and irrigation meters or are you proposing to use the
existing meter? Show location of all domestic and irrigation meters and show an easement if not
located in the City right-of-way.
5. Provide a 25' sanitary sewer easement for the line to the south of the property.
6. Show the sizes of all existing mains and verify the depth and separation of any crossings between
proposed services and existing utilities. Any clearance less than 24" will require concrete
encasement.
7. The connection to the 6" sanitary sewer will need to be made via a dry bore under Bethel School
Road, with an open cut of the asphalt paving only sufficient to make the connection.
8. Locations of all fire hydrants shall be approved by the City Fire Marshall, Travis Crump, at
(972)304-3503.
9. Please provide a drainage area map, showing existing and proposed (if any) drainage structures,
with a table showing drainage calculations. Also include a plat with your set of drawings.
There are various other comments throughout the plans. Once these comments have been addressed,
these marked plans and two sets of revised plans should be submitted to the City for review. If you
have any questions concerning these comments, contact me at (972) 304-7019.
Sincerely,
Kent M. Collins, E.I.T.