First United-CS 880609EST 1931 ~NC LAr. ;W FIRE PROTECt'ION CONTRACTOR'S MATERIAL 8. TEST CERTIFICATE FOR UNDERGROUND PIPING PROCEDURE Upon completion of work. inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. Al{ defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authoriti~s~'owners and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property Name Property Address PLANS INSTRUCTION,~ LOCATION UNDERGROUND PIPES AND JOINTS TEST DESCRIPTION FLUSHING TESTS Accepted By Approving Authority('s) Names Address Installation conforms to ~pcept~d plans Equipment used is opproved If no, exploJn deviations '[~"~'e s [] No Has person in charge of fire equipment been instructed as to location of control valves and care and maintenance of this new equipment If no. explain · ~"Yes [] No ,~'Yes [] No Have copies of appropriate instructions and care and maintenance charts been left on premises If no. explain Suppli~ Pipe Iyp~s and Class A D Type Joint Pipe conforms to Jl~'p~ Standard Fittings conform to .J~',ll~)~ Standard If no, explain Joints needing anchorage clamped, strapped, or blocked in accordance with NFPA . Standard If no, explain ,,~es [] No ~:'"~ s [] No FLUSHING. Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets such as hydrants and blow-offs. Flush at flows not less than 400 G PM {1514 L/rain) for 4-inch pipe. 600 G PM (2271 L/min) for 5 inch pipe, 750 GPM (2839 L/rain) for 6-inch pipe. 1000 GPM (3785 L/min) for 8-inch pipe, 1500 GPM (5678 L/min) for 10-inch pipe and 2000 GPM (7570 L/min) for 12-inch pipe. When supply cannot produce stipulated flow rates, obtain maximum available. HYDROSTATIC. Hydrostatic tests shall be made at not less than'200 psi (13.8 bars) for two hours or 5,~. psi (3.4 bars) above static pressure in excess of 150 psi (10.3 bars) for two hours. LEAKAGE. New pipe laid with rubber gasketed joints shall, if the workmanship is satisfactory, have little or no leakage at the joints The amount of leakage at the joints shall not exceed 2 qts. per hr. (1.89 L/h) per 100 joints irrespective of pipe dia meter. The leakage shall be distributed over all joints. If such leakage occurs at a few ioints the installation shall be considered unsatisfactory and necessary repairs made. The amount of allowable leakage specified above may be increased by 1 fl oz per in. valve diameter per hour (30 mL/25 mm/h) for each metal seated valve isolating the test section, If dry barrel hydrants are tested with the main valve open, so the hydrants are under pressure, an additional 5 oz per ninute (150 mL/min) leaka~le is permitted for each hydrant. New underground piping flushed according to NFPI~ Standard ~es [] No By (Company) If no, explain How Flushing Flow Was Obtained IThr°ugh What Type Opemng .~-Public Water [] Tank or Reservoir [] Fire Pump I [] Hydrant Butt. ~f"~pen Pipe Lead-ins flushed according to /1~_~'Plil~ . Standard [~'~'es [] No By (Company If no, explain How Flushing Flow Was Obtained Through What Type Opening' . ~r'Public Water [] Tank or Reservoir [] Fire Pump [] Y Conn. to Flange 8- Spigot [~pen Pipe LFP 4003 (Fl 12/82) (OVER) [] No HYDROSTATIC TEST LEAKAGE TEST HYDRANTS CONTROL VALVES REMARKS All New Underground Piping Hydros .... ~lly Tested At _ ~)O PSI for_ ~_ _ Hours Total Amount of Leakage Measured Gals. Hours Allowable Leakage Number Installed Gals. Hours Type and Make /AIl Operate Satisfactorily © Yes D No ,~Yes [] No Water control valves left wide open If no, state reason Hose treads of fire department connections and hydrants interchangeable with ~Yes ~ No those of fire department answering alarm Date Left in Service ;~ Name of Installing Contractor Title Date Additional Explanation and Notes BACK