Gulf Bearing-LR 950517Huntingdon
Engineering and Science for a Safer Environment
CLIENT:
PROJECT:
SERVICES:
Gulf Bearing, Inc.
Attn: Ross Ramsey
501 Industrial Blvd.
Grapevine, TX 76051
Huntingdon · Southwestern Laboratories
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telephone: (214) 631-2700
FAX: (214) 920-1891
REPORT OF
PLASTICITY INDEX OF SOILS
CLIENT NO.: 3200037
Gulf Bearing REPORT NO.: 24833
Coppell, Texas DATE OF SERVICE: 5/17/95
AUTHORIZATION: Ongoing
Obtain sample of material used for construction, prepare samples and
perform Liquid Limit and Plastic Limit tests and establish the Plasticity
Index of the material.
CONTRACTOR: Rogers O'Brien
SOURCE OF MATERIAL: Imported material
SAMPLE PREPARATION: Method A (Wet)
TEST METHOD: ASTM D4318, Proc. A
PROJECT DATA
SAMPLE LOCATION: Bldg pad Grid AI,
SAMPLED BY: Frank Tisdale, Cm.T
SOIL DESCRIPTION: Brown clayey sand
CLASSIFICATION: Not reported
REPORT OF TEST
2nd lift
LIQUID LIMIT: 2 5
PLASTIC LIMIT: 14
PLASTICITY INDEX: ll
REQUIREMENT~
Max/mum 36
Range 15. 1 E
Test results on this report
meet project specifications
as noted above.
Technician: Max Richwine
Weter
Content, w
33
31
29
27 ~
25 -"
5
10
LIQUID LIMIT DETERMINATION
Numberofblows
Report Distribution:
(1) Gulf Bearing, Inc.
(1) City of Coppe[[
(1) Gromatzky, Dup~ee & Associates (1) City of Coppe[[
(1) 8rockette,'Davfs, Drake
(2) Rogers O'Brien
(1) Southwestern Labs
(1) Southwestern Labs
I005
Our letters and reports ars for the exclulive u~e of the cl'
fu/I without the approval of the te~t' '-~ lerlt to whom the
apply ordy to the sample te~t.,~ ~,~ng :aoorotory. The ule of our-~ _.Y_~e ad~. reamed end shad! not be
~ --~/o,r Irt~ct~:l a~d are no- :-~:'-'-'~-"~ ,,~.u~z recelvo our writte~t a~m'OV,d .~., ~f, Uc~(s except n
....... u, apparently I~entlcal or similar
LABS
Huntingdon
Engineering and Science for a Safer Environment
Huntingdon · Southwestern Laboratories
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telephone: (214) 631-2700
FAX: {214) 920-1891
CLIENT:
Gulf Bearing, Inc.
Attn: Ross Ramsey
501 Industrial Blvd.
Grapevine, TX 76051
PROJECT: Gulf Bearing
Coppell, Texas
SERVICES: Perform in-place
of field compaction.
CONTRACTOR: Rogers O'Brien
TEST OF: Building pad fill
REPORT OF
IN-PLACE DENSITY
density and
CLIENT NO.: 3200037
REPORT NO.: 24704A
DATE OF SERVICE: 5/15/95
AUTHORIZATION: Ongoing
REPORT DATE: 5/17/95
moisture content tests to determine the degree
PROJECT DATA
MATERIALS
23937-Tannish bwn. clayey sand
MOISTURE/DENSITY RELATIONS
OPTIMUM MAXIMUM
MOISTURE % DENSITY gcf
10.5 123.5
METHOD OF TEST:
DENSITY: ASTM D2922
MOISTURE: ASTM D3017
SPECIFICATION
DENSITY: 95% MIN.
DENSITY
MOISTURE:-1 to +4% opt moist
TEST
NO LOCATION
1. Grid AJ, 1st lift.
2. Grid AK, 1st lift.
3. Grid BK, 1st lift.
4. Grid CK, 1st lift.
5. Grid DK, 1st lift.
6. Grid EK, 1st lift.
7. Grid FK, 1st lift.
REPORT OF TESTS
FIELD OPTIMUM
MOISTURE MOISTURE
14.0 10.5
12.9 10.5
11.4 10.5
12.7 10.5
11.5 10.5
12.8 10.5
12.7 10.5
FIELD MAXIMUM
DENSITY DENSITY DENSITY
{Pcf) {Pcf) (% max)
115.8 123.5 94
120.0 123.5 97
120.0 123.5 97
116.8 123.5 95
118.1 123.5 96
119.4 123.5 97
118.6 123.5 96
Report Of Tests Continued On Page 2
1007 LW
Our letter~ and report~ are for the exclusive cae of the client to whom they are addressed and ~ net be relxeducad except in
full without the approval of the tearing laboratory. The uae of ournarne rnu~t receive our written apfx~vd. Out letter~ and report~
apply only to the s~rnple te~ted and/or impacted, and are not indicative of the quentitie~ of apparently identical or ~imilar product~.
Huntingdon
Gulf Bearing, Inc.
CLIENT NO. 3200037
DATE OF SERVICE: 5/15/95
REPORT NO.
PAGE 2
24704A
REPORT OF TESTS (Continued)
FIELD OPTIMUM FIELD
TEST MOISTURE MOISTURE DENSITY
NO LOCATION {%~ {%} {Pcf~
8. Grid AJ, 1st lift.
(Retest) 13.6 10.5 115.9
9. Grid BJ, 1st lift. 12.0 10.5 118.8
10. Grid CJ, 1st lift. 12.7 10.5 115.0
11. Grid DJ, 1st lift. 13.0 10.5 116.7
12. Grid EJ, 1st lift. 12.6 10.5 118.9
13. Grid FJ, 1st lift. 12.0 10.5 118.9
14. Grid CJ, 1st lift. (Retest) 14.0 10.5 117.4
15. Grid AJ, 1st lift. (Retest) 13.9 10.5 117.0
MAXIMUM
DENSITY
{Pct~
123.5
123.5
123.5
123.5
123.5
123.5
123.5
123.5
An asterisk (*) appears next to test results which
do NOT meet the project specifications as noted on page 1.
DENSITY
{% max)
94
96
93
94
96
Technician: Frank Tisdale, CET Started: 12:30PM Stopped: 06:00PM
Report Distribution: (1) GuLf Bearing, Inc.
(1) Gr~matzky, Dupree & Associates
(1) Brockette, Davis, Drake
(2) Rogers O'Brien
(1) Southwestern Lalos
(1) Southwestern Labs
(1) City of CoppeLL
(1) City of CoppeLL
HUNTINGDON~eSOUTH LABS
F. Cook, P.E.
1007 LW
Our let~er~ end report~ are for th~ exclusive Lmm of th~ clier~ to whom they ~e od~l. res~od arid. shall net be r~pr~duced except in
full without the approval of the testing laboratory. The me of o~xnlme must recewe our wrlttall approval, uut lettorl ~ reportl
apply only to the sample tested and/or ir~oected, a~l a~a not indicative of the quentitie~ of appl~ently identical or ~imilar producTM.
Huntingdon
Engineering and Science for a Safer Environment
Huh ~,ngdon · Southwestern Laboratories
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telephone: (214) 631-2700
FAX: (214) 920-1891
REPORT OF
IN-PLACE DENSITY
CLIENT: Gulf Bearing, Inc.
Attn: Ross Ramsey
501 Industrial Blvd.
Grapevine, TX 76051
PROJECT: Gulf Bearing
Coppell, Texas
CLIENT NO.: 3200037
REPORT NO.: 24761
DATE OF SERVICE: 5/16/95
AUTHORIZATION: Ongoing
REPORT DATE: 5/17/95
SERVICES: Perform in-place density and moisture content tests to determine the degree
of field compaction.
CONTRACTOR: Rogers O'Brien
TEST OF: Utility backfill
PROJECT DATA
MATERIALS
23525-Dark brown clay
MOISTURE/DENSITY RI~LATIONS
OPTIMUM MAXIMUM
MOISTURE % DENSITY pcf
21.5 99.0
METHOD OF TEST:
DENSITY: ASTM D2922
MOISTURE: ASTM D3017
SPECIFICATION
DENSITY: 95% MIN. DENSITY
MOISTURE: opt and above
TEST
NO
1.
2.
3.
4.
LOCATION
8" S.S., Sra. 1+70, 1st lift.
8" S.S.. sra. 2+60, 1st lift.
8" S.S., sra. 1+80, 2nd lift.
Manhole, 8" S.S., Sta. 0+57,
south side, 1' below grade.
Manhole, 8" S.S., Sta. 0+57,
north side, final lift.
8" S.S., sra. 1+80, 3rd lift.
REPORT OF TESTS
FIELD OPTIMUM FIELD MAXIMUM
MOISTURE MOISTURE DENSITY DENSITY DENSITY
(%) {%) (Pcf} {Pcf) {% max}
24.3 21.5 99.4 99.0 100
25.1 21.5 95.4 99.0 96
24.1 21.5 93.7 99.0 95
24.0 21.5 100.4 99.0 101
23.6 21.5 97.1 99.0 98
24.5 21.5 95.9 99.0 97
Report Of Tests Continued On Page 2
1007 LW
Our letters and reports are for the exclusive u~e of the client to whom they ~'e ed~lrea~ed a~d ~ not ~ re~ ~t i~
full wit~ t~ epprovN of ~ t=i~ ~eboratory. T~ ~ of.~n~e m~t r~lve ~ ~n~en ap~ro~. ~ ,e~r~.n re~
apply ~y tO t~ sample t~t~ ~/~ I~, I~ ~e ~t i~lCltlVe o~ t~ q~tltl~ o~ ~p~ently i~lC~ or amll~ pr~.
Huntingdon
Gulf Bearing, Inc. REPORT NO.
CLIENT NO. 3200037 PAGE 2
DATE OF SERVICE: 5/16/95
24761
REPORT OF TESTS (Continued)
FIELD OPTIMUM FIELD MAXIMUM
TEST MOISTURE MOISTURE DENSITY DENSITY DENSITY
NO LOCATION (%) (%) (Pcf) (Pcf) (% maxi
7. 8" S.S., sra. 2+45, 2nd lift. 26.7 21.5 93.8 99.0 95
8. 8" S.S., Sta. 2+70, 4th lift. 24.8 21.5 98.2 99.0 99
9. 8" S.S., sra. 1+95, 4th lift. 23.0 21.5 98.2 99.0 99
10. 8" S.S., Sta. 2+50, 3rd lift. 25.6 21.5 96.1 99.0 97
Test results on this report meet project
specifications as noted on page 1.
ADDITIONALCOMMENTS:
Technician time recorded on report number 24760.
Technician: Frank Tisdale, CET
Report Distribution: ~
HUNTINGDON -.~ LABS
(1) GuLf Bearing, Inc. (1) City of Coppet[
(1) Gromatzky, Dupree & Associates (1) City of CoppeL[
(1) Brockette, Davis, Drake
(2) Rogers O'Brien F. King Cook, P.E.
(1) Southwestern Labs
(1) Southwestern Labs
1OO7 LW
Our lettem and reports al'e for the e.xclulive uae of the client to whom they are Id~lrealed I~d Ihaa net be re]~'educed except in
full without the approval of the te*ltmg lab.'army. The UII of oumame muir reeawe ~l' written ale.'oval. Uur letterl end ref)ertl
al3ply only to the simple teated end/or inspected, and le'e not indicative of the quantitiml of ~opll'ently identical o~ ~imillr productl.
Huntingdon
Enginee#ng and Science for a Safer Environment
HU,,angdon · Southwestern Laboratories
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telephone: {214) 631-2700
FAX: (214) 920-1891
REPORT OF
IN-PLACE DENSITY
CLIENT:
Gulf Bearing, Inc.
Attn: Ross Ramsey
501 Industrial Blvd.
Grapevine, TX 76051 CLIENT NO.: 3200037
REPORT NO.: 24762
PROJECT: Gulf Bearing DATE OF SERVICE: 5/16/95
Coppell, Texas AUTHORIZATION: Ongoing
REPORT DATE: 5/17/95
SERVICES: Perform in-place density and moisture content tests to determine the degree
of field compaction.
CONTRACTOR: Rogers O'Brien
TEST OF: Bldg. pad subgrade
PROJECT DATA
MATERIALS
23525-Dark brown clay
MOISTURE/DENSITY RELATIONS
OPTIMUM MAXIMUM
MOISTURE % DENSITY pof
21.5 99.0
METHOD OF TEST:
DENSITY: ASTM D2922
MOISTURE: ASTM D3017
SPECIFICATION
DENSITY: 95% MIN. DENSITY
MOISTURE: opt and above
REPORT OF TESTS
FIELD OPTIMUM FIELD MAXIMUM
TEST MOISTURE MOISTURE DENSITY DENSITY DENSITY
NO LOCATION {%) {%) {Pcf) {Pcf) {% max)
1. Grid AI, subgrade (Retest) 26.5 21.5 94.5 99.0 95
2. Grid BI, subgrade (Retest) 26.8 21.5 94.1 99.0 95
3. Grid CI, subgrade (Retest) 26.3 21.5 95.5 99.0 96
Test results on this report meet project
specifications as noted above.
ADDITIONAL COMMENTS:
Technician time recorded on report number 24760.
Technician: Frank Tisdale, CET
Report Distribution: ~Tr~IN LABS
(1) Gulf Bearing, [nc. (1) City of Coppe[[
(1) Gromatzky, Dupree & Associates (1) City of Coppe[[ .
(1) Brockette, Davis, Drake
(?) Rogers O'Brien F. K~CJ COO , ~
(1) Southwestern Labs.
(1) Southwestern Labs
1007 LW
Our letters and reports a~e for the exclulive uae of the cllen~ to whom they Ire id~rea~ed Ired. ~hall not b? re~oro~l, ._u~l ex?pt in
apply only to the sample te~ted and/or impacted, and Ire not indicative of the qulnl:jtie~ of ~ppIrently identical or similaz productl.
Huntingdon
Engineering and Sdence for a Safer Environment
Hu~ ,gdon *Southwestem Laboratories
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telephone: (214) 631-2700
FAX: {214) 920-1891
REPORT OF
IN-PLACE DENSITY
CLIENT: Gulf Bearing, Inc.
Attn: Ross Ramsey
501 Industrial Blvd.
'Grapevine, TX 76051
PROJECT: Gulf Bearing
Coppell, Texas
CLIENT NO.: 3200037
REPORT NO.: 24760
DATE OF SERVICE: 5/16/95
AUTHORIZATION: Ongoing
REPORT DATE: 5/17/95
SERVICES: Perform in-place density and moisture content tests to determine the degree
of field compaction.
CONTRACTOR: Rogers O'Brien
TEST OF: Building pad fill
PROJECT DATA
MATERIALS
MOISTURE/DENSITY RELATIONS
23937-Tannish brown clay sand 10.5
OPTIMUM MAXIMUM
MOISTURE % DENSITY pcf
123.5
METHOD OF TEST:
DENSITY: ASTM D2922
MOISTURE: ASTM D3017
SPECIFICATION
DENSITY: 95% MIN. DENSITY
MOISTURE:-1 TO +4% opt moist
REPORT OF TESTS
FIELD OPTIMUM FIELD MAXIMUM
TEST MOISTURE MOISTURE DENSITY DENSITY
NO LOCATION I%) (%) {Pcf) (Pc~
1. Grid FG, 1st lift. 12.2 10.5 118.8 123.5
2. Grid EG, 1st lift. 10.8 10.5 122.4 123.5
3. Grid DG, 1st lift. 14.2 10.5 117.4 123.5
4. Grid CG, 1st lift. 15.1 * 10.5 115.3 123.5
5. Grid BG, 1st lift. 13.7 10.5 116.0 123.5
6. Grid AG, 1st lift. 14.3 10.5 117.5 123.5
7. Grid BG, 1st lift, (Retest) 12.8 10.5 117.5 123.5
DENSITY
(% max)
96
99
95
93
94
95
95
Report Of Tests Continued On Page 2
1007 LW
Our letter~ ~nd reports ~re for the exclueive uee of the cfient to whom they ~e ~lreses¢l ~ Ihell not be reproduced ox?pt in
full without the approval of the testing Ilbm'ltoW. The ule of mx,mine mult rec~¥e our wntte~ aplwoval. Our letter~ arm re~ettl
apply o~ly tO the simple tested and/o~' inlpected, ~ al'e not indicative of the quantitie~ of apparently ide~ticld ol' ~imil~r ;xeduct~.
Huntingdon
Gulf Bearing, Inc. REPORT NO.
CLIENT NO. 3200037 PAGE 2
DATE OF SERVICE: 5/16/95
REPORT OF TESTS (contin~
24760
FIELD OPTIMUM FIELD MAXIMUM
TEST MOISTURE MOISTURE DENSITY DENSITY DENSITY
NO LOCATION {%) {%) (Pcf) {Pc~ {% max)
8. Grid CG, 1st lift, (Retest) 13.5 10.5 117.4 123.5 95
9. Grid AF, 5th lift. 14.2 10.5 117.2 123.5 95
10. Grid BF, 5th lift. 13.3 10.5 119.2 123.5 97
11. Grid CF, 5th lift. 13.9 10.5 117.0 123.5 95
12. Grid DF, 5th lift. 15.4 * 10.5 115.5 123.5 94 *
13. Grid EF, 5th lift. 12.4 10.5 119.6 123.5 97
14. Grid FF, 5th lift. 12.6 10.5 120.2 123.5 97
15. Grid AL, 2nd lift. 11.1 10.5 118.2 123.5 96
16. Grid BL, 2nd lift. 13.1 10.5 119.3 123.5 97
17. Grid CL, 2nd lift. 12.7 10.5 117.3 123.5 95
18. Grid DL, 2nd lift. 14.2 10.5 116.7 123.5 94 *
19. Grid EL, 2nd lift. 14.5 10.5 116.7 123.5 94 *
20. Grid FL, 2nd 'lift. 12.2 10.5 118.5 123.5 96
21. Grid AK, 2nd lift. 13.1 10.5 120.5 123.5 98
22. Grid BK, 2nd lift. 13.1 10.5 117.1 123.5 95
23. Grid CK, 2nd lift. 13.8 10.5 113.9 123.5 92 *
24. Grid DK, 2nd lift. 11.5 10.5 118.9 123.5 96
25. Grid EK, 2nd lift. 13.6 10.5 115.9 123.5 94 *
26. Grid FK, 2nd lift. 13.2 10.5 115.5 123.5 94 *
An asterisk (*) appears next to test results which
do NOT meet the project specifications as noted on page 1.
ADDITIONAL COMMENTS:
Technician time: 9:30am-ll:30am 12:30pm-4:30pm
Technician: Frank Tisdale, CET
Report Distribution: HHNTINGDONeSOUTHWF_~TERN LABS
(1) Gutf Bearing, Inc. (1) City of Coppett
(1) Gromatzky, Dupree & Associates (1) City of coppett
(1) Brockette, Davis, 0rake
(Z) Rogers O,Brien F. K~ng Coo , ~
(1) Southwestern Labs
(1) Southwestern Labs
f~l witho~ ~ ~provN of ~ t~tl~ I~at~y. T~ ~ of ~n~e m~ r~ewe ~ wrm~ ~provm. u~ et
apply ~y to t~ s~e t~ ~1~ i~, ~ ~e ~t iMicltive of t~ qu~tit~ M ep~mlly identical ~ ~mil~ pr~.
Huntingdon
Enginee#ng and Science for a Safer Environment
Huntingdon · Southwestern Laboratories
2575 Lone Star Dr. · P.O. Box 224227
Dallas. Texas 75222
Telephone: {214) 631-27OO
FAX: (214) 920-1891
REPORT OF
IN-PLACE DENSITY
CLIENT: Gulf Bearing, Inc.
Attn: Ross Ramsey
501 Industrial Blvd.
Grapevine, TX 76051
PROJECT: Gulf Bearing
Coppell, Texas
CLIENT NO.: 3200037
REPORT NO.: 24699
DATE OF SERVICE: 5/15/95
AUTHORIZATION: Ongoing
REPORT DATE: 5/17/95
SERVICES: Perform in-place density and moisture content tests to determine the degree
of field compaction.
CONTRACTOR: Rogers O'Brien
TEST OF: Building pad
subgrade
PROJECT DATA
MATERIALS
23525-Dark brown clay
MOISTURE/DENSITY RELATIONS
OPTIMUM MAXIMUM
MOISTURE % DENSITY pcf
21.5 99.0
METHOD OF TEST:
DENSITY: ASTM D2922
MOISTURE: ASTM D3017
SPECIFICATION
DENSITY: 95% MIN. DENSITY
MOISTURE: opt and above
TEST
NO
1.
2.
3.
4.
5.
6.
7.
LOCATION
Grid AH, subgrade (Retest)
Grid CH, subgrade (Retest)
Grid EH, subgrade (Retest)
Grid FI, subgrade
Grid EI, subgrade.
Grid DI, subgrade.
Grid CI, subgrade.
REPORT OF TESTS
FIELD OPTIMUM FIELD MAXIMUM
MOISTURE MOISTURE DENSITY DENSITY DENSITY
(%} (%) {Pcf) (~ (% max~
25.2 21.5 94.6 99.0 96
23.3 21.5 98.0 99.0 99
27.5 21.5 94.1 99.0 95
25.2 21.5 96.4 99.0 97
27.1 21.5 93.7 99.0 95
27.! 21.5 94.0 99.0 95
31.2 21.5 89.1 99.0 90 *
Report Of Tests Continued On Page 2
1007 LW
Huntingdon
Gulf Bearing, Inc.
CLIENT NO. 3200037
DATE OF SERVICE: 5/15/95
REPORT NO. 24699
PAGE 2
TEST
NO
8.
9.
REPORT OF TESTS ¢Conti.ued)
LOCATION
Grid BI, subgrade.
Grid AI, subgrade.
FIELD OPTIMUM FIELD MAXIMUM
MOISTURE MOISTURE DENSITY DENSITY DENSITY
(%1 (%) (Pcf[I IPcfI (% maxi
29.5 21.5 89.0 99.O 90
29.5 21.5 92.6 99.0 94
An asterisk (*) appears next to test results which
do NOT meet the project specifications as noted on page 1.
Technician: Frank Tisdale, CET
Report Distribution: (1) GuLf Bearing, [nc.
(1) Gromatzky, Dupree & Associates
(1) Brockette, Davis, Drake
(2) Rogers O'Brien
(1) Southwestern Labs
(1) City of Coppett
(1) City of Coppett
HUNTINGDO~BS
F. Kzng Cook,
(1) Southwestern Labs
1007 LW
Our I~ttetl and reportl ~e for the e?xclulive uae of t~ cl~ to wh~ ~y ~e ~r~ ~ ~ ~ ~ re~ ex~ in
ipp y ~ly to t~ s~ple t~ ~/or im~ct~, ~ ~e ~t I~lCitlVl of t~ qU~tltl~ ~ ~pee~y i~cM ~ amll~ ~.
Huntingdon
Engineering and Sdence for a Safer Environment
Huntingdon · Southwestern Laboratories
2575 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telephone: (214) 631-2700
FAX: (214) 920-1891
REPORT OF
IN-PLACE DENSITY
CLIENT:
Gulf Bearing, Inc.
Attn: Ross Ramsey
501 Industrial Blvd.
Grapevine, TX 76051 CEENTNO.: 3200037
REPORT NO.: 24656
PROJECT: Gulf Bearing DATE OF S£RV~CE: 5/14/95
Coppell, Texas AUTHORIZATION: Joe
REPORT DATE: 5/17/95
SERVICES: Perform in-place density and moisture content tests to determine the degree
of field compaction.
CONTRACTOR: Rogers O'Brien
TEST OF: Building pad
subgrade
PROJECT DATA
MATERIALS
23525-Dark brown clay
MOISTURE/DENSITY RELATIO, NS
OPTIMUM MAXIMUM
MOISTURE % DENSITY pcf
21.5 99.0
METHOD OF TEST:
DENSITY: ASTM D2922
MOISTURE: ASTM D3017
SPECIFICATION
DENSITY: 95% MIN. DENSITY
MOISTURE: opt and above
TEST
NO LOCATION
1. Grid FH, subgrade (Retest)
2. Grid EH, subgrade (Retest)
3. Grid DH, subgrade (Retest)
4. Grid CH, subgrade (Retest)
5. Grid BH, subgrade (Retest)
6. Grid AH, subgrade (Retest)
REPORT OF TESTS
FIELD OPTIMUM FIELD MAXIMUM
MOISTURE MOISTURE DENSITY DENSITY DENSITY
{%) {%) {Pcf) {Pcf) {% max)
26.6 21.5 94.4 99.0 95
31.0 21.5 90.9 99.0 92
27.2 21.5 94.0 99.0 95
33.1 21.5 88.3 99.0 89
26.0 21.5 94.9 99.0 96
32.5 21.5 90.6 99.0 92
An asterisk (*) appears next to test results which
do NOT meet the project specifications as noted above.
Technician: Frank Tisdale, CRT Started: 09:00AM Stopped: 01:00PM
Report Distribution:
(1) Gulf Bearing, [nc.
(1) 6romatzky, Dupree & Associates
(1) Brockette, Davis, Drake
(2) Rogers O'Brien
(1) Southwestern Labs
(1) City of Coppe[[
(1) City of
HUNTINGDON.S~~BS
F. King Cook, P.E.
(1) Southwestern Labs
100'/ LW
Ou~ letter~ and reports are fro' the exclusive uae of t~ clot to w~ t~y ~e ~r~ ~ ~1 ~t ~ r~ ex~ in
f~l witho~ t~ ~provel of t~ t~ti~ I~ratow. T~ ~ of ~ m~ re.lye ~ wr~ ~rovN. U~ ~s ~ r~o~
~ply ~y to t~ ~mple t~t~ ~/u i~, ~ ~e ~t iMicltive of t~ qu~tit~ of ~ently ~icN ~ ~mil~ ~.