Lakes of C 1stP-CS 851016 Maxim Engineers, Inc. Geotechnical Materials Testing Consultants October 16, 1985 Mr. Gary Burcham Triland Development, Inc. 5400 LBJ Freeway Suite 1000 Dallas, Texas 75240 Re: Concrete and Earthfill Placement Lakes of Coppell Dear Gary: In response to your request, we are pleased to submit our recommenda- tions for specifications for placement of concrete rubble at the referenced location. Concrete rubble used as earthfill should not be larger than 18 inches in diameter. Any rebar contained within the concrete should not extend outside the aforementioned 18-inch radius. Concrete larger than 18 inches should be broken down to acceptable size prior to or in-place before adding additional fill. Sufficient clay binder should be used along with the concrete rubble to ensure adequate compaction and to fill void spaces within the concrete rubble. Concrete rubble should not be placed within three (3) feet of the ground sur- face. We trust the information presented herein is in sufficient detail for your use. When we may be of further service, please do not hesitate to caU on us. Very truly yours, MAXIM ENGINEERS, INC. President GWP:md cc: Mr. Thomas J. Henkels, Sensen Construction Company Mr. Randy Flemming, Ginn, Inc. / 2342 Fabens PO. Box 59902 Dallas, Texas 75229 (214) 247-7575