Freeport NIP(2.5)-LR 980311 (2) E I--I r-4-- I I--I E E R In EB GEOTECHNICAL AND ENVIP, ONHENTAL CONSULTANTS REPORT OF FIELD DENSITY TESTS Northpoint Distribution Center Royal Lane at Northpoint Drive Coppell, Texas REPORTED TO: Myers & Crow Company, Ltd. REPORT NO. 12 3811 Turtle Creek Boulevard, Suite 730 REPORT DATE: 03-11-98 Dallas, Texas 75219 REG PROJECT NO. 4115 A'I-I'N: Mr. Richard Crow TECHNICIAN: S. Hope PAGE: 1 of 2 CONTRACTOR:. McFadden & Miller ............ ..................... ................................... .............................................. ................................. ................... 2 D-698 Yellowish to dark brown clay 26.5 92.0 129 02-11-98 Approach: 165'S,180'E(1) 0.0 95.3 24.1 1 97.7 130 Approach: 170'S,720'E(1) 0.0 95.5 24.4 1 97.9 131 Storm Line B: STA 1+20 5.8 93.5 24.6 1 95.9 132 Storm Line B: STA 1+25 5.0 94.0 24.4 1 96.4 133 Storm Line B: STA 1+30 4.3 94.8 23.7 1 97.2 134 Storm Line B: STA 1+35 3.5 93.9 24.8 1 96.3 135 Storm Line B: STA 1+45 2.3 94.3 24.8 1 96.7 136 02-12-98 Storm Line B: STA 1+55 1.5 95.0 23.7 1 97.4 137 Storm Line B: STA 1+65 0.8 94.7 24.0 1 97.1 138 Storm Line B: STA 1+70 0.0 93.6 23.5 1 96.0 139 02-13-98 Storm Line B: STA 2+50 6.0 94.0 24.1 1 96.4 140 Storm Line B: STA 2+75 5.3 93.3 24.8 1 95.7 141 Storm Line B: STA 2+90 4.5 93.7 24.3 1 96.1 142 Storm Line B: STA 3+20 3.8 94.1 24.3 1 96.5 143 Storm Line B: STA 3+40 3.0 94.5 24.3 1 96.9 144 Storm Line B: STA 3+45 2.3 94.1 24.8 1 96.5 145 Storm Line B: STA 3+60 1.5 93.3 24.3 1 95.7 146 Storm Line B: STA 3+70 0.8 94.5 23.7 1 96.9 147 Storm Line B: STA 3+80 0.0 94.3 24.4 1 96.7 2424 STUTZ DP,. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019 REPORT NO. 12 REPORT DATE: 03-11-98 REG PROJECT NO. 4115 PAGE: 2 of 2 148 02-14-98 Storm Line B: STA 5+00 3.0 93.3 24.9 1 95.7 149 Storm Line B: STA 5+20 2.3 94.5 24.2 1 96.9 150 Storm Line B: STA 5+40 1.5 93.7 24.0 1 96.1 151 Storm Line B: STA 5+60 0.8 93.5 24.7 1 95.9 152 Storm Line B: STA 5+80 0.0 93.4 24.5 1 95.8 Comments: Where tested, materials were in compliance with project specifications. Footnotes: (1) Measurements referenced from S.W. building corner. Distribution: (4) Myers & Crow Company, Ltd./ Submitted by: Mr. Richard Crow (1) AECC, Inc./Mr. Andy Brundige REED ENGINEERING GROUP, INC. (1) Dockery Engineering/ Mr. Bill Wray Original Signed By (1) McFadden & Miller/ Mr. Jon Jacobson Ronald F. Reed, P.E. (1) Halff Associates/Mr. Pat Acker KENrls (1) Pritchard Associates/ Mr. Jim Pritchard (1) O'Brien & Associates/ Mr. Mick Granlund (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone