Freeport NIP(2.5)-LR 980326GEOTECHNICAL AND ENVIRONMENTAL CONSULTANTS REPORT OF FIELD DENSITY TESTS Northpoint Distribution Center Royal Lane at Northpoint Drive Coppell, Texas REPORTED TO: Myers & Crow Company, Ltd. REPORT NO. 24 3811 Turtle Creek Boulevard REPORT DATE: 03-26-98 Suite 730 REG PROJECT NO. 4115 Dallas, Texas 75219 TECHNICIAN: S. Hope ATTN: Mr. Richard Crow PAGE: 1 of CONTRACTOR: McFadden & Miller 1 D-698 Dark gray clay 22.0 97.5 2 D-698 Yellowish to dark brown clay 26.5 92.0 3 D-698 Light brown & gray clayey sand 10.5 122.0 4 D-698 Light brown clayey sand, "select" fill 10.5 120.0 343 03-03-98 Bldg Pad: 75'S,75'E(1) 1.0 93.0 26.3 1 95.4 345 Bldg Pad: 125'S,75'E(1) 1.0 92.9 25.9 1 95.3 346 Bldg Pad: 200'S,75'E(1) 1.0 93.3 25.7 1 95.7 347 Bldg Pad: 175'S,125'E(1) 1.0 93.7 25.6 1 95.5 348 Bldg Pad: 125'S,225'E(1) 1.0 92.8 26.1 1 95.2 349 03-04-98 8"Waterline: STA24+00 3.0 94.0 24.3 1 96.4 350 8"Waterline: STA 23+90 2.3 94.5 23.3 1 96.9 351 8"Waterline: STA 23+80 1.5 95.0 22.9 1 97.4 352 8"Waterline: STA 23+70 0.8 95.8 23.2 1 98.3 353 8"Waterline: STA 23+60 0.0 94.7 23.0 1 97.1 354 8"Waterline: STA 22+50 3.0 95.5 23.4 1 97.9 355 8"Waterline: STA 22+40 2.3 95.8 23.7 1 98.3 356 8"Waterline: STA 22+30 1.5 95.1 24.2 1 97.5 357 8"Waterline: STA 22+25 0.8 95.9 23.5 1 98.4 358 8"Waterline: STA 22+20 0.0 94.6 23.3 1 97.0 359 03-05-98 Ctr Medium across from SW 0.0 94.8 23.9 1 97.2 Paving Approach 360 Ctr Medium across from S 0.0 95.5 23.6 1 97.9 Paving Approach 361 Bldg Pad: 50'S,50'W(1) 0.5 115.9 10.8 3 95.0 362 Bldg Pad: 100'S,50'W(1) 0.5 116.5 11.1 3 95.5 363 Bldg Pad: 150'S,35'W(1) 0.5 116.7 11.7 3 95.7 364 Bldg Pad: 200'S,30'W(1) 0.5 116.6 10.7 3 95.6 365 BIdg Pad: 230'S,30'W(1) 0.5 115.9 11.2 3 95.0 366 Bldg Pad: 50'S,100'W(1) 0.5 116.5 11.7 3 95.5 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019 367 03-05-98 Bldg Pad: 100'S,90'W(1) 0.5 116.9 11.0 3 95.8 368 Bldg Pad: 150'S,100'W(1) 0.5 117.0 10.9 3 95.9 369 03-06-98 Bldg Pad: 200'S,100'W(1) 0.5 118.1 11.7 3 96.8 370 Bldg Pad: 240'S,90'W(1) 0.5 118.7 10.9 3 97.3 371 Bldg Pad: 50'S,200'W(1) 0.5 117.7 11.7 3 96.5 372 Bldg Pad: 90'S,200'W(1) 0.5 119.0 11.3 3 97.5 373 Bldg Pad: 140'S,200'W(1) 0.5 117.3 11.3 3 96.1 374 Bldg Pad: 200'S,200'W(1) 0.5 117.5 12.3 3 96.3 375 Bldg Pad: 240'S,200'W(1) 0.5 117.3 11.8 3 96.1 376 Bldg Pad: 20'S,300'W(1 ) 0.5 118.0 11.9 3 96.7 377 Bldg Pad: 80'S,300'W(1 ) 0.5 117.9 11.6 3 96.6 378 Bldg Pad: 130'S,300'W(1) 0.5 118.1 11.0 3 96.8 379 03-09-98 Waterline: STA20+20 3.0 94.3 24.8 1 96.7 380 Waterline: STA 20+10 2.3 94.0 24.3 1 96.4 381 Waterline: STA 20+05 1.5 93.8 24.5 1 96.2 382 Waterline: STA 19+95 0.8 94.1 24.5 1 96.5 383 Waterline: STA 19+90 0.0 94.2 24.9 1 96.6 384 Waterline: STA 21+20 3.0 95.0 23.4 1 97.4 385 Waterline: STA 21+10 2.3 94.5 24.0 1 96.9 386 Waterline: STA 21+05 1.5 93.5 24.2 1 95.9 387 Waterline: STA 21+00 0.8 93.0 24.7 1 95.4 388 Waterline: STA 21+30 0.0 94.0 23.9 1 96.4 389 03-10-98 Waterline: STA 18+80 3.0 94.5 24.4 1 96.9 390 Waterline: STA 18+75 2.3 93.3 24.5 1 95.7 391 Waterline: STA 18+70 1.5 93.7 24.9 1 96.1 392 Waterline: STA 18+65 0.8 94.5 24.3 1 96.9 393 Waterline: STA 18+60 0.0 95.0 24.7 1 97.4 394 03-11-98 Bldg Pad: 50'S,400'W(1) 0.5 116.5 11.2 3 95.5 395 Bldg Pad: 100'S,400'W(1) 0.5 117.1 10.8 3 96.0 396 Bldg Pad: 150'S,400'W(1) 0.5 116.6 11.3 3 95.6 397 Bldg Pad: 200'S,400'W(1) 0.5 116.8 11.6 3 95.7 398 Bldg Pad: 240'S,400'W(1) 0.5 116.1 11.9 3 95.2 399 Bldg Pad: 30'S,500'W(1) 0.5 116.1 11.4 3 95.2 400 Bldg Pad: 100'S,500'W(1) 0.5 116.6 12.1 3 95.6 401 Bldg Pad: 150'S,500'W(1) 0.5 117.4 11.6 3 96.2 402 Bldg Pad: 200'S,500'W(1) 0.5 116.5 11.4 3 95.5 403 Bldg Pad: 235'S,500'W(1) 0.5 116.0 11.6 3 95.1 404 03-12-98 Bldg Pad: 50'S,600'W(1) 1.0 92.9 25.8 1 95.3 405 Bldg Pad: 100'S,600'W(1) 1.0 92.6 25.4 1 95.0 406 Bldg Pad: 150'S,600'W(1) 1.0 93.3 24.7 1 95.7 407 Bldg Pad: 200'S,600'W(1) 1.0 93.5 25.0 1 95.9 408 BIdg Pad: 240'S,600'W(1) 1.0 93.1 25.0 1 95.5 409 03-13-98 BIdg Pad: 20'S,700'W(1) 1.0 93.3 25.1 1 95.7 410 Btdg Pad: 90'S,700'W(1) 1.0 92.9 25.5 1 95.2 411 Bldg Pad: 140'S,700'W(1) 1.0 93.1 25.2 1 95.5 412 Bldg Pad: 190'S,700'W(1) 1.0 93.2 24.8 1 95.6 413 03-13-98 Bldg Pad: 235'S,700'W(1) 1.0 92.7 25.0 1 95.1 414 Bldg Pad: 40'S,800'W(1) 1.0 92.8 26.0 1 95.2 415 Bldg Pad: 100'S,800'W(1) 1.0 92.9 26.1 1 95.3 416 Bldg Pad: 150'S,800'W(1) 1.0 93.1 25.8 I 95.5 417 Bldg Pad: 200'S,800'W(1) 1.0 93.5 25.3 1 95.9 418 Bldg Pad: 240'S,800'W(1) 1.0 93.0 25.4 1 95.4 419 Bldg Pad: 35'S,900'W(1) 1.0 93.4 26.1 1 95.8 420 Bldg Pad: 85'S,900'W(1) 1.0 93.5 26.3 1 95.9 421 Bldg Pad: 140'S,900'W(1) 1.0 92.7 26.4 1 95.1 422 Bldg Pad: 190'S,900'W(1) 1.0 92.9 25.3 1 95.3 423 Bldg Pad: 235'S,900'W(1) 1.0 94.0 25.5 1 96.4 424 BId9 Pad: 50'S,1000'W(1) 1.0 92.8 26.3 1 95.2 425 Bldg Pad: 100'S,1000'W(1) 1.0 93.3 25.9 1 95.7 426 Bldg Pad: 150'S,1000'W(1) 1.0 93.0 25.4 1 95.3 427 Bldg Pad: 200'S,1000'W(1) 1.0 93.2 26.1 1 95.6 428 Bldg Pad: 240'S,1000'W(1) 1.0 93.1 25.8 1 95.5 429 Bldg Pad: 50'S,1100'W(1) 1.0 93.0 25.5 1 95.4 430 Bldg Pad: 100'S,1100'W(1) 1.0 93.5 26.0 1 95.9 431 Bldg Pad: 150'S,1100'W(1) 1.0 92.8 25.4 1 95.2 432 Bldg Pad: 200'S,1100'W(1) 1.0 93.4 25.1 1 95.8 433 Bldg Pad: 240'S,1100'W(1) 1.0 92.6 26.2 1 95.0 434 Bldg Pad: 50'S,1200'W(1) 1.0 92.9 25.5 1 95.3 435 Bldg Pad: 100'S,1190'W(1) 1.0 93.9 25.6 1 96.3 436 Bldg Pad: 150'S,1190'W(1) 1.0 94.1 25.1 1 96.5 437 Bldg Pad: 200'S,1190'W(1) 1.0 94.0 25.8 1 96.4 438 Bldg Pad: 240'S,1190'W(1) 1.0 93.6 26.0 1 96.0 439 03-14-98 Bldg Pad: 40'S,500'W(1) 0.0 117.5 11.5 3 96.3 440 Bldg Pad: 100'S,500'W(1) 0.0 118.0 11.3 3 96.7 441 Bldg Pad: 150'S,500'W(1) 0.0 118.8 11.9 3 97.4 442 Bldg Pad: 200'S,500'W(1) 0.0 117.9 10.8 3 96.6 443 Bldg Pad: 240'S,500'W(1) 0.0 118.3 10.7 3 97.0 444 Bldg Pad: 50'S,400'W(1) 0.0 118.8 11.0 3 97.4 445 Bldg Pad: 100'S,400'W(1) 0.0 117.8 11.5 3 96.6 446 Bldg Pad: 150'S,400'W(1) 0.0 118.5 11.4 3 97.1 447 Bldg Pad: 200'S,400'W(1) 0.0 118.1 10.9 3 96.8 448 Bldg Pad: 240'S,400'W(1) 0.0 117.7 11.3 3 96.5 449 Bldg Pad: 40'S,300'W(1) 0.0 116.9 11.9 3 95.8 450 Bldg Pad: 100'S,300'W(1) 0.0 116.8 12.0 3 95.7 451 Bldg Pad: 150'S,300'W(1) 0.0 117.7 11.8 3 96.5 452 Bldg Pad: 200'S,300'W(1) 0.0 118.5 11.9 3 97.1 453 Bldg Pad: 240'S,300'W(1) 0.0 117.9 12.0 3 96.6 454 Bldg Pad: 30'S,200'W(1 ) 0.0 117.7 11.5 3 96.5 455 Bldg Pad: 85'S,200'W(1) 0.0 118.0 11.1 3 96.7 456 Bldg Pad: 140'S,200'W(1) 0.0 118.5 10.9 3 97.1 457 Bldg Pad: 200'S,200'W(1 ) 0.0 117.9 11.4 3 96.6 458 Bldg Pad: 235'$,200'W(1 ) 0.0 117.5 11.7 3 96.3 459 03-14-98 Bldg Pad: 25'S,100'W(1) 0.0 119.0 10.5 3 97.5 460 Bldg Pad: 100'S,100'W(1) 0.0 119.3 10.8 3 97.8 461 Bldg Pad: 150'S,100'W(1) 0.0 118.4 10.7 3 97.0 462 Bldg Pad: 200'S,100'W(1) 0.0 117.5 11.0 3 96.3 463 Bldg Pad: 240'S,100'W(1) 0.0 118.4 11.4 3 97.0 464 Bldg Pad: 50'S,25'W(1) 0.0 117.8 12.0 3 96.6 465 Bldg Pad: 100'S,25'W(1) 0.0 118.8 10.8 3 97.4 466 Bldg Pad: 150'S,30'W(1) 0.0 119.0 10.3 3 97.5 467 Bldg Pad: 200'S,35'W(1) 0.0 119.9 10.5 3 98.3 468 Bldg Pad: 240'S,40'W(1) 0.0 118.8 11.4 3 97.4 469 Waterline: STA 15+00 3.0 93.3 24.5 1 95.7 470 Waterline: STA 14+90 2.3 94.0 25.0 1 96.4 471 Waterline: STA 14+80 1.5 93.6 24.4 1 96.0' 472 Waterline: STA 14+70 0.8 94.4 25.1 1 96.8 473 Waterline: STA 14+60 0.0 95.0 24.6 1 97.4 474 Waterline: STA 16+50 97.0 23.8 1 99.5 475 Waterline: STA 16+40 94.8 24.9 1 97.2 476 Waterline: STA 16+30 95.0 24.8 1 97.4 477 Waterline: STA 16+20 94.7 24.4 1 97.1 478 Waterline: STA 16+10 93.3 24.9 1 95.7 Comments: Where tested, materials were in compliance with project speCifications. Footnotes: (1) Measurements referenced from N.E. building corner. Distribution: (4) Myers & Crow Company, Ltd./ Submitted by: Mr. Richard Crow (1) AECC, Inc./Mr. Andy Brundige REED ENGINEERING GROUP, INC. (1) Dockery Engineering/ Mr. Bill Wray Original Signed By (1) McFadden & Miller/ Mr. Jon Jacobson Ronald F. Reed, P.E. (1) Halff Associates/Mr. Pat Acker RFR/cav (1) Pritchard Associates/ Mr. Jim Pritchard (1) O'Brien & Associates/ Mr. Mick Granlund (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone