Loading...
ST0004-LR010814 (2) ~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax.'(972) 488-8080 Concrete Compression Test Report Client: The City of Coppell Report Distribution: (1) The City of Coppell Project: Freeport Parkway Pavement (1) Quantam Contracting Repair TMI Report No.: DC01-066-034 Report Date: 08/14/2001 Specifications Test Data Strength 4000 psi @ 28 Days Placement Date 08/02/2001 Slump 5 in max Sampled By Adrain Hayes Air Content 3 % min 6 % max Weather Clear Concrete Temperature n/a Supplier/Mix Hanson/9636 Ambient Temperature n/a Air Content Method ASTM C-231-B Ticket Number: 937496 Time Batched: 12:45 pm Time Sampled: 1:50 pm Slump: 5 in Air Content: 5.7 % Unit Weight: n/a Concrete Temperature: 97° F Ambient Temperature: 100° F Yardage (c.y.): 110 of 130 Placement Location: Station 14+00 to Station 27+50 Sample Location: Station 17+00 Set # Cylinder Age. Max Load Area Strength Fracture Test Date ~ (lbs. force) (sq.in.) (ps~ Type 2 08020107 08/09/2001 7~ 117940 28.27 4170~ unbonded cap 2 08020108 08/09/2001 120660 28.27 4270 ~, unbonded cap 2 08020109 08/16/2001 2 08020110 08/16/2001 14 2 08020111 08/30/2001 28 2 08020112 08/30/2001 28 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. TERRA-MAR, INC.  ' Sr. Vice President The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. Page 2 or'2