Loading...
ST0004-LR010814 (3) ~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080 ---- Concrete Compression Test Report Client: The City of Coppell Report Distribution: (1) The City of Coppell Project: Freeport Parkway Pavement (1) Quantam Contracting Repair TMI Report No.: DC01-066-034 Report Date: 08/14/2001 Specifications Test Data Strength 4000 psi @ 28 Days Placement Date 08/02/2001 Slump 5 in max Sampled By Adrain Hayes Air Content 3 % min 6 % max Weather Clear Concrete Temperature n/a Supplier/Mix Hanson/9636 Ambient Temperature n/a Air Content Method ASTM C-231-B Ticket Number: 937433 Time Batched: 10:33 am Time Sampled: 11:45 am Slump: 5.5 in* Air Content: 4.5 % Unit Weight: n/a Concrete Temperature: 96° F Ambient Temperature: 98° F Yardage (c.y.): 10 of 130 Placement Location: North side of Freeport Pkwy. Sample Location: Station 14+00 to Station 7+50 An asterisk (*) appears next to field data which does NOT meet specifications. Cyl~der Age. Max Load Area Strenqth Fracture Set Test Date (days) (lbs. force) (sq.in.) (ps~ Type 1 08020101 08/09/2001 ~t 106690 28.27 3770 unbonded cap 1 08020102 08/09/2001 ~ 103100 28,27 3650 ~ unbonded cap I 08020103 08/16/2001 14 I 08020104 08/16/2001 14 I 08020105 08/30/2001 28 I 08020106 08/30/2001 28 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. ~ SCOTTM. pETTi? ~ ~.'":' ............*'*'*"*'"~""S TI=RR~-M~R, INC. ~ The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. 01SSD Page I of 2