ST0004-LR010813 (6) ~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON /~ 'STIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972~ ~,88-8800 fax:(972) 488-8080 -- Concrete Compression Test Report Client: The City of Coppell Report Distribution: (1) The City of Coppell Project: Freeport Parkway Pavement (1) Quantam Contracting Repair TMI Report No.: DC01-066-030 Report Date: 08/13/2001 Specifications Test Data Strength 4000 psi @ 28 Days Placement Date 07/27/200-1 Slump 5 in max Sampled By Randolph Shaheed Air Content 3 % min 6 % max Weather Clear / Hot Concrete Temperature n/a Supplier/Mix Hanson/9636 Ambient Temperature n/a Air Content Method ASTM C-231-B Ticket Number: 797954 Time Batched: 12:30 pm Time Sampled: 2:00 pm Slump: 5 in Air Content: 8.5 %* Unit Weight: n/a Concrete Temperature: 100° F Ambient Temperature: 101° F Yardage (c.y.): 40 OF 110 Placement Location: Paving at Freeport Sample Location: At Station 11+50 An asterisk (*) appears next to field data which does NOT meet specifications. , ,,.Con~re[e Comae!on Te~ ReSults ;~'~ : Set # Cyl~der Age Max Load Area Strength Fracture Test Date (days) (lbs. force) (sq.in.) (psi} Type 1 07270101 08/03/2001 7 73680 28.27 26.~.....~ unbonded cap 1 07270102 08/03/2001 7 72970 28.27 ~ unbonded cap 1 07270103 08/10/2001 14 B4780 28.27 unbonded cap 1 07270104 08/10/2001 14 91590 28.27 unbonded cap 1 07270105 08/24/2001 28 1 07270106 08/24/2001 28 Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. TE~A-~A~, I~C. ~ / Sr. Vice ~msidont Tho rosults prosontod in this re~ort ~o~ain only to the specific itoms testod. This report was produce~ for l~e, oxclusivo use of the cliont. Any reproduction of th~s report, or any cart theroin, is strictly prohibited without the ox~ross written consent of IMI. rossi) Page I o1'1