Freeport NIP(6)-LR 981020CONTRA CT INSPECTION SER VICE, Inc.
Project:
Client:
4305 Glenwood Ct. Granbury, TX 76049
North Point Distribution Center
Coppell, TX
Reed Engineering Group
2424 Stutz, Suite 400
Dallas, TX 75235
(817) 246-8096 FAX (817) 246-5889
REPORT OF
METAL DECK INSPECTION
Report No: 10981-8
Attention: Keith Atkins
Date of Service: 10-20-98
Page 1 of 1
Drawings utilized:
REPORT OF INSPECTION
Contract Documents
Locations/item inspected:
Column line 7 to 11 and grid line A to G
Discrepancies/comments:
A visual reinspection of report dated 7-16-98 was conducted from underneath on the above reference
project with results as follows.
1.) Side lap screws have been installed and found to comply.
2.) By weld indications on joist, welds appear to have been corrected.
Tim Glazier CWI #98020281
Technician
,/.~nntract Inspection Service
This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said client