Freeport NIP(6)-LR 980713CONTRA CT INSPECTION SER VICE, Inc.
4305 Glenwood Ct. Granbury, TX 76049 (817) 246-8096 FAX (817) 246-5889
REPORT OF
METAL DECK INSPECTION
Project:
Client:
I
Freeport North - Building 4
Coppell, TX
Reed Engineering Group
2424 Stutz, Suite 400
Dallas, TX 75235
Drawings utilized:
Report No: 9911-8
Attention: Keith Atkins
Date of Service: 07-13-98
Page 1 of 1
REPORT OF INSPECTION
Contract Document/AWS D 1.1-96
Locations/item inspected:
Column line 1 to 5 and grid line L to T
Discrepancies/comments:
A visual inspection was conducted on the above referenced project with results as follows:
* 1.) Deck support perimeter angle was found non-compliant due to joints not welded
together.
2.) Steel deck was found to comply for:
a.) weld pattern
b.) puddle weld size
c.) side lap screw installation
Technician ~/Cfontract Inspection Service
This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said client